Socomec Diris A 10 DIN-Rail Mount Power Meter

Model: 4825U010

Socomec Diris A 10 DIN-Rail Mount Power Meter

Model: 4825U010

A revenue grade class 0.5, compact, DIN-rail mount power & energy meter with LCD display - no communications.

A revenue grade class 0.5, compact, DIN-rail mount power & energy meter with LCD display - no communications.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output-

Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Model: AcuRev-1312-333-X1 | Order No: AcuRev 1312-333-X1

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts 333 mV current transformer (CT) input, measures neutral current with the fourth CT and provides residual current measurement.


Accuenergy AcuRev 1312-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output-

Accuenergy AcuRev 1312-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Model: AcuRev-1312-5A-X1 | Order No: AcuRev 1312-5A-X1

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts field configurable current transformer (CT) input, and measures neutral current with the fourth CT.


Not what you're looking for? Let’s do a search and help you find what you need.


Modular multi function meter

The DIRIS A10 is a revenue grade class 0.5 multi function meter for measuring electrical values in low voltage networks in modular format. It allows all electrical parameters to be displayed and the measurement, energy metering and communication functions to be used. In addition, the DIRIS A10 has a function for correcting errors in CT connections. It also allows variations in temperature to be detected thanks to its internal temperature measurement function.


Key Features

  • Multi-measurement and metering
  • THD voltages and currents up to level 51
  • Programmable hour meter
  • Alarm management
  • RS485 Jbus/Modbus communication
  • Dual tariff function
  • 4 DIn modules
  • ANSI C12.2 certified
The Socomec Diris A10 Setup

Specifications

Multi-function meter

  • Current
    • instantaneous: I1, I2, I3, In
    • maximum average: I1, I2, I3, In
  • Voltages & frequency
    • instantaneous: U1, U2, U3, U12, U23, U31, F
  • Power
    • instantaneous: 3P, ΣP, 3Q, ΣQ, 3S, ΣS
    • maximum average: ΣP, ΣQ, ΣS
  • Power factor
    • instantaneous: 3PF, ΣPF
  • Internal temperature Metering

Metering

  • Active energy: + kWh
  • Reactive energy: + kvarh
  • Hours

Harmonic analysis

  • Total harmonic distortion (level 51)
    • Currents: thd I1, thd I2, thd I3
    • Phase-to-neutral voltage: thd U1, thd U2, thd U3
    • Phase to phase voltage: thd U12, thd U23, thd U31

Dual tariff function
Selection of one out of 2 billing tariffs

Events
Alarms on all electrical values

Communications
RS485 (JBUS/MODBUS) digital

Output

  • Remote comand of apparatus
  • Alarm report
  • Pulse report

Input
Remote control

The Socomec Diris A10 Unit Overview

  1. Backlit LCD screen.
  2. Direct access key for currents (instant and maximum) and current THD.
  3. Direct access key for voltages, frequency and voltage THD.
  4. Direct access key for active, reactive and apparent power (instantaneous and max. values) and power factor.
  5. Direct access key for energies and hour meter.
  6. Pushbutton for currents, temperatures and CT setup wiring correction.
  7. Metrological LED.

What's included with the Socomec 4825U010

  • Socomec Diris A 10 DIN-Rail Mount Power Meter

Click on a category to view a selection of compatible accessories with the Socomec Diris A 10 DIN-Rail Mount Power Meter.

Flex-Core 1708SC Shorting Block 1708SC
Shorting block with 8 terminals and cover for use in electrical applications.




Flex-Core 1706SC Shorting Block 1706SC
Shorting block with 6 terminals and cover for use in electrical applications.




Flex-Core 1704SC Shorting Block 1704SC
Shorting block with 4 terminals and cover for use in electrical applications.




Flex-Core 3VTL-460-240 Potential Transformer 3VTL-460-240
3-Phase potential transformer for 240:120V line-to-line and 2:1 turns ratio.




Flex-Core 3VTN-460-277-FF Potential Transformer 3VTN-460-277-FF
3-Phase potential transformer for 277:120V line-to-neutral and 2.31:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-208 Potential Transformer 3VTL-460-208
3-Phase potential transformer for 208:120V line-to-line and 1.73:1 turns ratio




Flex-Core 3VTN-460-346-FF Potential Transformer 3VTN-460-346-FF
3-Phase potential transformer for 346:120V line-to-neutral and 2.88:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse




Flex-Core 3VTN-460-300-FF Potential Transformer 3VTN-460-300-FF
3-Phase potential transformer for 300:120V line-to-neutral and 2.5:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse




Flex-Core 3VTN-460-288-FF Potential Transformer 3VTN-460-288-FF
3-Phase potential transformer for 288:120V line-to-neutral and 2.4:1 turns ratio. Comes complete with primary and secondary fuse




Flex-Core 3VTN-460-240-FF Potential Transformer 3VTN-460-240-FF
3-Phase potential transformer for 240:120V line-to-neutral and 2:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-120 Potential Transformer 3VTL-460-120
3-Phase potential transformer for 120:120V line-to-line and 1:1 turns ratio.




Flex-Core 3VTN-460-120-FF Potential Transformer 3VTN-460-120-FF
3-Phase potential transformer for 120:120V line-to-neutral and 1:1 turns ratio. Comes complete with 4A primary and 1.6A secondary fuse.




Flex-Core 3VTN-460-069-FF Potential Transformer 3VTN-460-069-FF
3-Phase potential transformer for 69.3:120V line-to-neutral and 0.58:1 turns ratio. Comes complete with 5A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-480 Potential Transformer 3VTL-460-480
3-Phase potential transformer for 480:120V line-to-line and 4:1 turns ratio.




Flex-Core 3VTL-460-288 Potential Transformer 3VTL-460-288
3-Phase potential transformer for 288:120V line-to-line and 2.4:1 turns ratio




Flex-Core 3VTN-460-208-FF Potential Transformer 3VTN-460-208-FF
3-Phase potential transformer for 208:120V line-to-neutral and 1.73:1 turns ratio. Comes complete with primary and secondary fuse.




Ask a question about Socomec Diris A 10 DIN-Rail Mount Power Meter

Customer Reviews for the Socomec 4825U010

Modular multi function meter

The DIRIS A10 is a revenue grade class 0.5 multi function meter for measuring electrical values in low voltage networks in modular format. It allows all electrical parameters to be displayed and the measurement, energy metering and communication functions to be used. In addition, the DIRIS A10 has a function for correcting errors in CT connections. It also allows variations in temperature to be detected thanks to its internal temperature measurement function.


Key Features

  • Multi-measurement and metering
  • THD voltages and currents up to level 51
  • Programmable hour meter
  • Alarm management
  • RS485 Jbus/Modbus communication
  • Dual tariff function
  • 4 DIn modules
  • ANSI C12.2 certified
The Socomec Diris A10 Setup

Specifications

Multi-function meter

  • Current
    • instantaneous: I1, I2, I3, In
    • maximum average: I1, I2, I3, In
  • Voltages & frequency
    • instantaneous: U1, U2, U3, U12, U23, U31, F
  • Power
    • instantaneous: 3P, ΣP, 3Q, ΣQ, 3S, ΣS
    • maximum average: ΣP, ΣQ, ΣS
  • Power factor
    • instantaneous: 3PF, ΣPF
  • Internal temperature Metering

Metering

  • Active energy: + kWh
  • Reactive energy: + kvarh
  • Hours

Harmonic analysis

  • Total harmonic distortion (level 51)
    • Currents: thd I1, thd I2, thd I3
    • Phase-to-neutral voltage: thd U1, thd U2, thd U3
    • Phase to phase voltage: thd U12, thd U23, thd U31

Dual tariff function
Selection of one out of 2 billing tariffs

Events
Alarms on all electrical values

Communications
RS485 (JBUS/MODBUS) digital

Output

  • Remote comand of apparatus
  • Alarm report
  • Pulse report

Input
Remote control

The Socomec Diris A10 Unit Overview

  1. Backlit LCD screen.
  2. Direct access key for currents (instant and maximum) and current THD.
  3. Direct access key for voltages, frequency and voltage THD.
  4. Direct access key for active, reactive and apparent power (instantaneous and max. values) and power factor.
  5. Direct access key for energies and hour meter.
  6. Pushbutton for currents, temperatures and CT setup wiring correction.
  7. Metrological LED.

What's included with the Socomec 4825U010

  • Socomec Diris A 10 DIN-Rail Mount Power Meter

Click on a category to view a selection of compatible accessories with the Socomec Diris A 10 DIN-Rail Mount Power Meter.

Flex-Core 1708SC Shorting Block 1708SC
Shorting block with 8 terminals and cover for use in electrical applications.




Flex-Core 1706SC Shorting Block 1706SC
Shorting block with 6 terminals and cover for use in electrical applications.




Flex-Core 1704SC Shorting Block 1704SC
Shorting block with 4 terminals and cover for use in electrical applications.




Flex-Core 3VTL-460-240 Potential Transformer 3VTL-460-240
3-Phase potential transformer for 240:120V line-to-line and 2:1 turns ratio.




Flex-Core 3VTN-460-277-FF Potential Transformer 3VTN-460-277-FF
3-Phase potential transformer for 277:120V line-to-neutral and 2.31:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-208 Potential Transformer 3VTL-460-208
3-Phase potential transformer for 208:120V line-to-line and 1.73:1 turns ratio




Flex-Core 3VTN-460-346-FF Potential Transformer 3VTN-460-346-FF
3-Phase potential transformer for 346:120V line-to-neutral and 2.88:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse




Flex-Core 3VTN-460-300-FF Potential Transformer 3VTN-460-300-FF
3-Phase potential transformer for 300:120V line-to-neutral and 2.5:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse




Flex-Core 3VTN-460-288-FF Potential Transformer 3VTN-460-288-FF
3-Phase potential transformer for 288:120V line-to-neutral and 2.4:1 turns ratio. Comes complete with primary and secondary fuse




Flex-Core 3VTN-460-240-FF Potential Transformer 3VTN-460-240-FF
3-Phase potential transformer for 240:120V line-to-neutral and 2:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-120 Potential Transformer 3VTL-460-120
3-Phase potential transformer for 120:120V line-to-line and 1:1 turns ratio.




Flex-Core 3VTN-460-120-FF Potential Transformer 3VTN-460-120-FF
3-Phase potential transformer for 120:120V line-to-neutral and 1:1 turns ratio. Comes complete with 4A primary and 1.6A secondary fuse.




Flex-Core 3VTN-460-069-FF Potential Transformer 3VTN-460-069-FF
3-Phase potential transformer for 69.3:120V line-to-neutral and 0.58:1 turns ratio. Comes complete with 5A primary and 1.6A secondary fuse




Flex-Core 3VTL-460-480 Potential Transformer 3VTL-460-480
3-Phase potential transformer for 480:120V line-to-line and 4:1 turns ratio.




Flex-Core 3VTL-460-288 Potential Transformer 3VTL-460-288
3-Phase potential transformer for 288:120V line-to-line and 2.4:1 turns ratio




Flex-Core 3VTN-460-208-FF Potential Transformer 3VTN-460-208-FF
3-Phase potential transformer for 208:120V line-to-neutral and 1.73:1 turns ratio. Comes complete with primary and secondary fuse.




Ask a question about Socomec Diris A 10 DIN-Rail Mount Power Meter

Customer Reviews for the Socomec 4825U010

More Socomec Products

Calibration Lab