Measures the mass of the fluids directly, rather than volume, thus, does not require compensations for factors such as temperature and pressure. It consists of two parallel tubes that are made to oscillate using a magnet and features 1 1/2" size and accuracy of ±0.2%.
Measures the mass of the fluids directly, rather than volume, thus, does not require compensations for factors such as temperature and pressure. It consists of two parallel tubes that are made to oscillate using a magnet and features 1 1/2" size and accuracy of ±0.2%.
Designed to suit your need to measure almost any fluid, across any application. Built on the Coriolis principle, these meters measure the mass of the fluids directly, rather than volume. This means they do not require compensations for factors such as temperature and pressure which impact volume and in turn, impact the accuracy of measurement.
This flowmeter consists of two parallel tubes that are made to oscillate using a magnet. These oscillations are recorded by sensors fitted at the inlet and outlet of each tube. In a no-flow state, the oscillations are synchronized, i.e. in phase with each other, since there is no mass exerting any force on the tubes. On the other hand, any fluid, or gas flowing through the tubes generates Coriolis forces, causing the tubes to twist in proportion to the mass flow rate of the medium.
The magnitude of this twisting is measured by the sensors as a phase shift between the inlet and outlet of the tubes; this phase shift is used to measure the mass flow rate of the medium.
Features
Applications
Repeatability | ±0.1% |
Accuracy | ±0.2% |
Size | 1 1/2" |
Density Accuracy | 0.001 g/cm3 |
Sensor | Micro-bend shaped |
Process Media | Liquid, Gas |
Transmitter | Digital type/Analog type |
Power Supply | 18 to 28 VDC |
Maximum Pressure | 3770 psi (26 MPa) |
Output Signal | 4 to 20 mA and pulse, optional: Modbus RS485 |
Process Connections | ANSI flanges |
Electronics | Direct mount |
Diagnostic Functions | Reset totalizer |
Graphic Display | OLED |
Operating Elements | 3 optical keys for operator |
Additional Features | Low cut, Oil and water content analysis, Zero calibration, Flow calibration, Long-term stability, Zero point adjustment, Conforms IEC 61362 (Industrial) EMC directive |
Temperature Range | -58 to 257°F (-50 to 125°C) |
Process Medium Temperature | Up to -328°F (-200°C) |
Repeatability | ±0.1% |
Accuracy | ±0.2% |
Size | 1 1/2" |
Density Accuracy | 0.001 g/cm3 |
Sensor | Micro-bend shaped |
Process Media | Liquid, Gas |
Transmitter | Digital type/Analog type |
Power Supply | 18 to 28 VDC |
Maximum Pressure | 3770 psi (26 MPa) |
Output Signal | 4 to 20 mA and pulse, optional: Modbus RS485 |
Process Connections | ANSI flanges |
Electronics | Direct mount |
Diagnostic Functions | Reset totalizer |
Graphic Display | OLED |
Operating Elements | 3 optical keys for operator |
Additional Features | Low cut, Oil and water content analysis, Zero calibration, Flow calibration, Long-term stability, Zero point adjustment, Conforms IEC 61362 (Industrial) EMC directive |
Temperature Range | -58 to 257°F (-50 to 125°C) |
Process Medium Temperature | Up to -328°F (-200°C) |