Ideally suited for basic measurements on heating systems, this analyzer combines simple functions with high accuracy. In addition, this kit includes a combustion analyzer, a rechargeable battery, a probe, a power supply, a cable, a hose, five particle filters, a USB-C cable, a case, a printer, and a certificate of conformity.
Ideally suited for basic measurements on heating systems, this analyzer combines simple functions with high accuracy. In addition, this kit includes a combustion analyzer, a rechargeable battery, a probe, a power supply, a cable, a hose, five particle filters, a USB-C cable, a case, a printer, and a certificate of conformity.
Simultaneous, individual measurement and display of all measurement parameters (O2, CO, CO2, flue gas, ambient temperature, CO environment, draught, and pressure) is simple with this combustion analyzer's easy and intuitive guidance menu. Long battery lifetimes of more than eight hours guarantee the analyzer is always ready. Furthermore, the analyzer is easily configurable via the Testo Smart App. A combination of easy handling and a compact design make this gas analyzer a robust tool for daily work, even when things get rough.
Specially developed for this combustion analyzer, the Bluetooth™ printer allows for clear on-site reporting as required. Through a simple connection to the Testo Smart App, print the current measurement value from any menu during or after the measurement. Moreover, this analyzer and printer combination makes simultaneous digital documentation, data transfer, and digital customer data management measurements possible.
Features
Applications
Measurements | |
Temperature (Flue Gas) | Measuring range: 32 to 752°F (0 to 400°C) Accuracy ±1 digit: ±1.8°F (32 to 212°F)/±1°C (0 to 100°C) ±1.5% of mv (>212°F)/±1.5% of mv (>100°C) Resolution: 0.1°F (0.1°C) Adjustment time t90: <50 seconds |
Temperature (Ambient Temperature) | Measuring range: -4 to 212°F (-20 to 100°C) Accuracy ±1 digit: ±2°F (±1°C) Resolution: 0.1°F (0.1°C) Adjustment time t90: <50 seconds |
Draft Measurement | Measuring range: -8 to 8 "H2O (-20 to 20 hPa) Accuracy ±1 digit: ±0.01 "H2O (-1.2 to 1.2 "H2O) ±0.03 hPa (-3 to 3 hPa) ±1.5% of mv (remaining range) Resolution: 0.01 "H2O (0.01 hPa) |
Pressure Measurement | Measuring range: -16 to 16 "H2O (-40 to 40 hPa) Accuracy ±1 digit: ±0.2 "H2O (±0.5 hPa) Resolution: 0.1 "H2O (0.1 hPa) |
O2 Measurement | Measuring range: 0 to 21% volume Accuracy ±1 digit: ±0.2% volume Resolution: 0.1% volume Adjustment time t90: 30 seconds |
CO Measurement (without H2- compensation) | Measuring range: 0 to 4000 ppm Accuracy ±1 digit: ±20 ppm (0 to 400 ppm) ±5% of mv (401 to 2000 ppm) ±10% of mv (2001 to 4000 ppm) Resolution: 1 ppm Adjustment time t90: 60 seconds |
Ambient CO Measurement | Measuring range: 0 to 4000 ppm Accuracy ±1 digit: ±20 ppm (0 to 400 ppm) ±5% of mv (401 to 2000 ppm) ±10% of mv (2001 to 4000 ppm) Resolution: 1 ppm Adjustment time t90: 60 seconds |
Pollution Degree | PD2 |
Efficiency Testing (ETA) | Measuring range: 0 to 120% Resolution: 0.1% ppm |
Protection Class | IP40 |
Flue Gas Loss | Measuring range: 0 to 99.9% Resolution: 0.1% |
General Specifications | |
Environmental Conditions | Storage temperature: -4 to 122°F (-20 to 50°C) Operating temperature: 23 to 113°F (-5 to 45°C) Humidity application range: 0 to 80% RH |
Operating Altitude | ≤6562' (≤2000 m) |
Memory | Reports saved within Testo Smart App |
Display | Graphic seven-line display |
Power Supply | Rating: 4 W Supply: 5 V/1 A, USB charger (connection via USB-C) Rechargeable battery: 1500 mAh Battery charge time: approximately eight hours |
Operating Altitude | ≤6562' (≤2000 m) |
Dimensions | 8 x 3 x 2" (201 x 83 x 44 mm) |
Weight | Approximately 1.5 lbs (660 g) |
Click on a category to view a selection of compatible accessories with the Testo 310 II Combustion Analyzer Kit with printer, 32 to 752°F, 0 to 4000 ppm.
Measurements | |
Temperature (Flue Gas) | Measuring range: 32 to 752°F (0 to 400°C) Accuracy ±1 digit: ±1.8°F (32 to 212°F)/±1°C (0 to 100°C) ±1.5% of mv (>212°F)/±1.5% of mv (>100°C) Resolution: 0.1°F (0.1°C) Adjustment time t90: <50 seconds |
Temperature (Ambient Temperature) | Measuring range: -4 to 212°F (-20 to 100°C) Accuracy ±1 digit: ±2°F (±1°C) Resolution: 0.1°F (0.1°C) Adjustment time t90: <50 seconds |
Draft Measurement | Measuring range: -8 to 8 "H2O (-20 to 20 hPa) Accuracy ±1 digit: ±0.01 "H2O (-1.2 to 1.2 "H2O) ±0.03 hPa (-3 to 3 hPa) ±1.5% of mv (remaining range) Resolution: 0.01 "H2O (0.01 hPa) |
Pressure Measurement | Measuring range: -16 to 16 "H2O (-40 to 40 hPa) Accuracy ±1 digit: ±0.2 "H2O (±0.5 hPa) Resolution: 0.1 "H2O (0.1 hPa) |
O2 Measurement | Measuring range: 0 to 21% volume Accuracy ±1 digit: ±0.2% volume Resolution: 0.1% volume Adjustment time t90: 30 seconds |
CO Measurement (without H2- compensation) | Measuring range: 0 to 4000 ppm Accuracy ±1 digit: ±20 ppm (0 to 400 ppm) ±5% of mv (401 to 2000 ppm) ±10% of mv (2001 to 4000 ppm) Resolution: 1 ppm Adjustment time t90: 60 seconds |
Ambient CO Measurement | Measuring range: 0 to 4000 ppm Accuracy ±1 digit: ±20 ppm (0 to 400 ppm) ±5% of mv (401 to 2000 ppm) ±10% of mv (2001 to 4000 ppm) Resolution: 1 ppm Adjustment time t90: 60 seconds |
Pollution Degree | PD2 |
Efficiency Testing (ETA) | Measuring range: 0 to 120% Resolution: 0.1% ppm |
Protection Class | IP40 |
Flue Gas Loss | Measuring range: 0 to 99.9% Resolution: 0.1% |
General Specifications | |
Environmental Conditions | Storage temperature: -4 to 122°F (-20 to 50°C) Operating temperature: 23 to 113°F (-5 to 45°C) Humidity application range: 0 to 80% RH |
Operating Altitude | ≤6562' (≤2000 m) |
Memory | Reports saved within Testo Smart App |
Display | Graphic seven-line display |
Power Supply | Rating: 4 W Supply: 5 V/1 A, USB charger (connection via USB-C) Rechargeable battery: 1500 mAh Battery charge time: approximately eight hours |
Operating Altitude | ≤6562' (≤2000 m) |
Dimensions | 8 x 3 x 2" (201 x 83 x 44 mm) |
Weight | Approximately 1.5 lbs (660 g) |
Click on a category to view a selection of compatible accessories with the Testo 310 II Combustion Analyzer Kit with printer, 32 to 752°F, 0 to 4000 ppm.