TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A

Model: 265 | UPC: 637623002656

TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A

Model: 265 | UPC: 637623002656

Covering all the basic electrical functions with additional features of data hold, frequency, capacitance and extra large numerals for easy viewing.

Covering all the basic electrical functions with additional features of data hold, frequency, capacitance and extra large numerals for easy viewing.

Sale Price $51.26 USD
Regular Price $59.95 USD
Availability 1 to 2 Weeks
Quantity

Traceable In-House Calibration Certificate for your 265 Digital Clamp Meter with Digital Multimeter Functions

Traceable In-House Calibration Certificate for your 265 Digital Clamp Meter with Digital Multimeter Functions

TPI 265 Offers

Features

  • Slim jaw and body design for use is crowded electrical panels
  • Capacitance up to 4,000 micro-farads
  • Up to 400 AC amps with 0.01 resolution
  • Diode, resistance and audible continuity
  • CAT III 600V rated; cULus 61010
  • Test start and run capacitors
  • Measure heat anticipator current
  • Determine thermocouple voltage
  • Test line and control voltages
  • Measure heating element resistance
  • Measure and adjust variable frequency drives

Applications

  • Test start and run capacitors
  • Measure heat anticipator current
  • Determine thermocouple voltage
  • Test line and control voltages
  • Measure heating element resistance
  • Measure and adjust variable frequency drives

HVAC/R

  • DCmV - Thermocouples in furnaces
  • ACA - Heat anticipator current in thermostats
  • ACV - Line voltage
  • ACV or DCV - Control circuit voltage
  • OHMS - Compressor winding resistance
  • OHMS - Continuity of wiring
  • CAP - Motor start and run capacitors
  • ACA - Motor and compressor start up current
  • Hz - Frequency on controls and line voltage

Electrical

  • ACV - Measure line voltage
  • ACA - Measure line current
  • OHMS - Continuity of circuit breakers
  • DCV - Voltage of direct drive DC motors
  • ACA - Start up current of motors, relays, contractors and transformers

Electronic

  • ACV - Measure power supply voltage
  • ACA - Measure power supply current
  • OHMS - Continuity of circuit breakers and fuses

TPI 265 Specifications

Basic DC Accuracy 0.5%
DC Voltage Maximum: 600V
Resolution: 0.1mV
AC Voltage Maximum: 600V
Resolution: 0.1mV
AC Amps Maximum: 400A
Resolution: 0.01A
Resistance Maximum: 40MΩ
Resolution: 0.1Ω
Frequency Maximum: 400MHz
Resolution: 0.001KHz
Capacitance Maximum: 4,000μF
Resolution: 0.001nF
Diode Test Current Max: 1.5mA
Continuity Buzzer sounds at approx 35Ω Response time; 50ms
Click here for complete specifications on the TPI 265

What's Included with the TPI 265

  • Digital Clamp Meter
  • Test Lead Set
  • Soft Carrying Case
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A.

TPI A771 Carbon Monoxide Adapter for Digital Multimeters and Clamp-on Meters A771
Use alongside your DMM and measure the atmospheres air CO.




Ask a question about TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A

Customer Reviews for the TPI 265

TPI 265 Offers

Features

  • Slim jaw and body design for use is crowded electrical panels
  • Capacitance up to 4,000 micro-farads
  • Up to 400 AC amps with 0.01 resolution
  • Diode, resistance and audible continuity
  • CAT III 600V rated; cULus 61010
  • Test start and run capacitors
  • Measure heat anticipator current
  • Determine thermocouple voltage
  • Test line and control voltages
  • Measure heating element resistance
  • Measure and adjust variable frequency drives

Applications

  • Test start and run capacitors
  • Measure heat anticipator current
  • Determine thermocouple voltage
  • Test line and control voltages
  • Measure heating element resistance
  • Measure and adjust variable frequency drives

HVAC/R

  • DCmV - Thermocouples in furnaces
  • ACA - Heat anticipator current in thermostats
  • ACV - Line voltage
  • ACV or DCV - Control circuit voltage
  • OHMS - Compressor winding resistance
  • OHMS - Continuity of wiring
  • CAP - Motor start and run capacitors
  • ACA - Motor and compressor start up current
  • Hz - Frequency on controls and line voltage

Electrical

  • ACV - Measure line voltage
  • ACA - Measure line current
  • OHMS - Continuity of circuit breakers
  • DCV - Voltage of direct drive DC motors
  • ACA - Start up current of motors, relays, contractors and transformers

Electronic

  • ACV - Measure power supply voltage
  • ACA - Measure power supply current
  • OHMS - Continuity of circuit breakers and fuses

TPI 265 Specifications

Basic DC Accuracy 0.5%
DC Voltage Maximum: 600V
Resolution: 0.1mV
AC Voltage Maximum: 600V
Resolution: 0.1mV
AC Amps Maximum: 400A
Resolution: 0.01A
Resistance Maximum: 40MΩ
Resolution: 0.1Ω
Frequency Maximum: 400MHz
Resolution: 0.001KHz
Capacitance Maximum: 4,000μF
Resolution: 0.001nF
Diode Test Current Max: 1.5mA
Continuity Buzzer sounds at approx 35Ω Response time; 50ms
Click here for complete specifications on the TPI 265

What's Included with the TPI 265

  • Digital Clamp Meter
  • Test Lead Set
  • Soft Carrying Case
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A.

TPI A771 Carbon Monoxide Adapter for Digital Multimeters and Clamp-on Meters A771
Use alongside your DMM and measure the atmospheres air CO.




Ask a question about TPI 265 Digital Clamp Meter with Digital Multimeter Functions, DC 600V/AC 400A

Customer Reviews for the TPI 265

More TPI Products

Calibration Lab