Triplett 2001 Railroad Test Set with 100Hz and 250Hz Cab Filters

Model: 2001 | Order No: 2011 | UPC: 614395001148

Triplett 2001 Railroad Test Set with 100Hz and 250Hz Cab Filters

Model: 2001 | Order No: 2011 | UPC: 614395001148

This model is designed for passenger railroads using 100Hz and 250Hz coding systems. The all pass position bypasses cab filters.

This model is designed for passenger railroads using 100Hz and 250Hz coding systems. The all pass position bypasses cab filters.

Sale Price $1509.71 USD
Regular Price $1899.00 USD
Availability 9 to 10 Weeks
Quantity

Traceable In-House Calibration Certificate for your 2011 Railroad Test Set with 100Hz and 250Hz Cab Filters

Traceable In-House Calibration Certificate for your 2011 Railroad Test Set with 100Hz and 250Hz Cab Filters

Triplett 2001 Offers

The 2000 Series Railroad Testers from Triplett Test Equipment and Tools are specialized Test Sets designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment.

The 2000 Series is compatible with older test technologies, yet is easier to use, and offers test features not found on earlier test sets. Fewer jacks, more ranges, and a logical front panel layout all contribute to the 2000 Series' ease of use. A precision multi-turn Ohms Adjust Control facilitates accurate resistance measurements. Also, the measurement of relay contact On Time has been simplified and expanded requiring no adjustments.

Code Parameter measurements have been made simpler and more accurate. No longer is it necessary to count pointer swings to measure. On Time can be measured on live signals as well as relay contacts. Peak levels can be determined quickly and automatically. Adjustments to the code equipment peak level can be made without constantly readjusting the Test Set.

Features

  • 100Hz and 250Hz Cab Filters
  • Auto Polarity in DC functions
  • Selectable DC Amp polarity
  • Direct measurement of Code Parameters
  • Relay Contact On Time (Dry Contact) requires no adjustment
  • Ohmmeter Voltage Mode detects either polarity voltage including AC
  • Field replaceable protective window
  • All Pass position bypasses Cab Filters

Applications

Ideal for the following applications: Rapid Transit, Commuter Trains, Passenger Railroads

Triplett 2001 Specifications

DC Voltage
Ranges 0.6, 3, 15, 60, and 300 VDC
Accuracy ±1.5% of full scale
Sensitivity 1000 Ohms per Volt
DC Milliamps
Ranges 15, 60, and 300 mA DC
Accuracy ±1.5% of full scale
Burden Volts 60 mV nominal
AC Voltage
Ranges 1.5, 3, 15, 150, 300, and 600 VAC
Accuracy ±3.0% of full scale
Sensitivity 288 Ohms per Volt
AC Amps
Ranges 1.5, 6, and 30 Amps AC
Accuracy ±3.0% of full scale
Burden Volts 60 mV nominal
Meter Movement
Electrical 100 µA ±1% at full scale
Construction Taut band, shock mounted, mirrored scale
Click here for complete specifications on the Triplett 2001

What's included with the Triplett 2001

  • 2001 Railroad Test Set
  • Test Leads
  • Padded Water Repellent Carrying Case
  • Shoulder Strap
  • Batteries
  • Manual

Ask a question about Triplett 2001 Railroad Test Set with 100Hz and 250Hz Cab Filters

Customer Reviews for the Triplett 2001

Triplett 2001 Offers

The 2000 Series Railroad Testers from Triplett Test Equipment and Tools are specialized Test Sets designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment.

The 2000 Series is compatible with older test technologies, yet is easier to use, and offers test features not found on earlier test sets. Fewer jacks, more ranges, and a logical front panel layout all contribute to the 2000 Series' ease of use. A precision multi-turn Ohms Adjust Control facilitates accurate resistance measurements. Also, the measurement of relay contact On Time has been simplified and expanded requiring no adjustments.

Code Parameter measurements have been made simpler and more accurate. No longer is it necessary to count pointer swings to measure. On Time can be measured on live signals as well as relay contacts. Peak levels can be determined quickly and automatically. Adjustments to the code equipment peak level can be made without constantly readjusting the Test Set.

Features

  • 100Hz and 250Hz Cab Filters
  • Auto Polarity in DC functions
  • Selectable DC Amp polarity
  • Direct measurement of Code Parameters
  • Relay Contact On Time (Dry Contact) requires no adjustment
  • Ohmmeter Voltage Mode detects either polarity voltage including AC
  • Field replaceable protective window
  • All Pass position bypasses Cab Filters

Applications

Ideal for the following applications: Rapid Transit, Commuter Trains, Passenger Railroads

Triplett 2001 Specifications

DC Voltage
Ranges 0.6, 3, 15, 60, and 300 VDC
Accuracy ±1.5% of full scale
Sensitivity 1000 Ohms per Volt
DC Milliamps
Ranges 15, 60, and 300 mA DC
Accuracy ±1.5% of full scale
Burden Volts 60 mV nominal
AC Voltage
Ranges 1.5, 3, 15, 150, 300, and 600 VAC
Accuracy ±3.0% of full scale
Sensitivity 288 Ohms per Volt
AC Amps
Ranges 1.5, 6, and 30 Amps AC
Accuracy ±3.0% of full scale
Burden Volts 60 mV nominal
Meter Movement
Electrical 100 µA ±1% at full scale
Construction Taut band, shock mounted, mirrored scale
Click here for complete specifications on the Triplett 2001

What's included with the Triplett 2001

  • 2001 Railroad Test Set
  • Test Leads
  • Padded Water Repellent Carrying Case
  • Shoulder Strap
  • Batteries
  • Manual

Ask a question about Triplett 2001 Railroad Test Set with 100Hz and 250Hz Cab Filters

Customer Reviews for the Triplett 2001

More Triplett Products

Calibration Lab