Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.
Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.
This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.
Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The balometer capture hood helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.
The capture hood features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.
Features
Applications
Velocity Range | |
Pitot Probes | 25 to 15,500 ft/min (0.125 to 78 m/s) |
Air Flow Probe | 25 to 5,000 ft/min (0.125 to 25 m/s) |
Velocity Matrix | 25 to 2,500 ft/min (0.125 to 12.5 m/s) |
Accuracy | ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s) |
Resolution | 1 ft/min (0.01 m/s) |
Pressure | |
Differential Pressure | ±15 inH2O (±3735 Pa) 150 inH2O (37.5 kPa) Maximum safe operating pressure |
Absolute Pressure | 15 to 40 inHg (356 to 1016 mmHg) |
Accuracy | ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential ±2% of reading absolute |
Resolution | 0.00001 inH2O (0.001 Pa) static and differential 0.01 inHg (1 mmHg) absolute |
General Specifications | |
Instrument Temperature Range | Operating: 40 to 140°F (4.4 to 60°C) Storage: -4 to 160°F (-20 to 71°C) |
Weight | 7.4 lbs (3.4 kg) |
Click on a category to view a selection of compatible accessories with the TSI EBT731-STA Balometer Capture Hood with stand and tablet.
Velocity Range | |
Pitot Probes | 25 to 15,500 ft/min (0.125 to 78 m/s) |
Air Flow Probe | 25 to 5,000 ft/min (0.125 to 25 m/s) |
Velocity Matrix | 25 to 2,500 ft/min (0.125 to 12.5 m/s) |
Accuracy | ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s) |
Resolution | 1 ft/min (0.01 m/s) |
Pressure | |
Differential Pressure | ±15 inH2O (±3735 Pa) 150 inH2O (37.5 kPa) Maximum safe operating pressure |
Absolute Pressure | 15 to 40 inHg (356 to 1016 mmHg) |
Accuracy | ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential ±2% of reading absolute |
Resolution | 0.00001 inH2O (0.001 Pa) static and differential 0.01 inHg (1 mmHg) absolute |
General Specifications | |
Instrument Temperature Range | Operating: 40 to 140°F (4.4 to 60°C) Storage: -4 to 160°F (-20 to 71°C) |
Weight | 7.4 lbs (3.4 kg) |
Click on a category to view a selection of compatible accessories with the TSI EBT731-STA Balometer Capture Hood with stand and tablet.