With its dual display, the True RMS clamp meter can display several results simultaneously. Ideal for low-level voltage detection and wide temperature range measurements, the meter features a test lead storage, a magnetic mount and comes complete with a pipe clamp adapter.
With its dual display, the True RMS clamp meter can display several results simultaneously. Ideal for low-level voltage detection and wide temperature range measurements, the meter features a test lead storage, a magnetic mount and comes complete with a pipe clamp adapter.
Features
Applications
DC Amps - Jaw Input Range | |
400 µA | Resolution: 0.01 A Accuracy: ± (2.0% +5 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 A Accuracy: ± (1.5% + 5 dgts) Overload protection: 2000 µA / 600 V RMS |
DC Low Amps Range | |
400 µA | Resolution: 0.01 µA Accuracy: ± (1.2% +3 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 µA Accuracy: ± (1.2% +3 dgts) Overload protection: 2000 µA / 600 V RMS |
Test Lead Input Range | |
400 µA | Resolution: 0.01 A Accuracy: ± (2.0% +5 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 A Accuracy: ± (1.5% + 5 dgts) Overload protection: 2000 µA / 600 V RMS |
AC Volts Ranges | |
400 mV | Resolution: 0.1 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
4 V | Resolution: 1 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
40 V | Resolution: 10 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
400 V | Resolution: 100 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
7500 V | Resolution: 1 V Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
Temperature | |
-22 to 14°F (-30 to -10°C) | Resolution: 0.1°F (0.1°C) Accuracy: ± (1.0% + 5.4°F) ± (1.0% + 3.0°C) Overload protection: 30 V RMS |
15 to 752°F (-9 to 400°C) | Resolution: 0.1°F (0.1°C) Accuracy: ± (1.0% + 3.6°F) ± (1.0% + 2.0°C) Overload protection: 30 V RMS |
DC Amps - Jaw Input Range | |
400 µA | Resolution: 0.01 A Accuracy: ± (2.0% +5 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 A Accuracy: ± (1.5% + 5 dgts) Overload protection: 2000 µA / 600 V RMS |
DC Low Amps Range | |
400 µA | Resolution: 0.01 µA Accuracy: ± (1.2% +3 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 µA Accuracy: ± (1.2% +3 dgts) Overload protection: 2000 µA / 600 V RMS |
Test Lead Input Range | |
400 µA | Resolution: 0.01 A Accuracy: ± (2.0% +5 dgts) Overload protection: 2000 µA / 600 V RMS |
2000 µA | Resolution: 0.1 A Accuracy: ± (1.5% + 5 dgts) Overload protection: 2000 µA / 600 V RMS |
AC Volts Ranges | |
400 mV | Resolution: 0.1 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
4 V | Resolution: 1 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
40 V | Resolution: 10 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
400 V | Resolution: 100 mV Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
7500 V | Resolution: 1 V Accuracy: ± (2.0% +5 dgts) Overload protection: 750 V RMS |
Temperature | |
-22 to 14°F (-30 to -10°C) | Resolution: 0.1°F (0.1°C) Accuracy: ± (1.0% + 5.4°F) ± (1.0% + 3.0°C) Overload protection: 30 V RMS |
15 to 752°F (-9 to 400°C) | Resolution: 0.1°F (0.1°C) Accuracy: ± (1.0% + 3.6°F) ± (1.0% + 2.0°C) Overload protection: 30 V RMS |