The wall CO2 sensor with dual analog output is a non-dispersive infrared analyzer designed for measuring CO2 concentration in office and living spaces.

The wall CO2 sensor with dual analog output is a non-dispersive infrared analyzer designed for measuring CO2 concentration in office and living spaces.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Veris CWV2 Economy Wall Mount CO<sub>2</sub> Sensor-

Veris CWV2 Economy Wall Mount CO2 Sensor

Model: CWV2

Air quality sensors for living space are for use with BAS controllers designed to accept 4 to 20mA, 0 to 5 Vdc or 0 to 10 Vdc outputs.


Not what you're looking for? Let’s do a search and help you find what you need.


Veris CWVS1XX1 Offers

The wall CO₂ sensor with dual analog output is a non-dispersive infrared analyzer designed for measuring CO₂ concentration in office and living spaces.

Features

  • Non-dispersive infrared technology repeatable to ±30 ppm ±4.5% of measured value
  • Innovative self-calibration algorithm easy to maintain
  • 5-year calibration interval (recommended)
  • Improve comfort and facilitate compliance with ASHRAE 62.1-2004 standard for air quality
  • Helps with green branding initiatives
  • Dual analog outputs for added user convenience
  • LED indication for power and error detection reduces time spent troubleshooting
  • Switchable 0 to 3/5/10 V output gives increased flexibility
  • US and European mounting holes provide installation flexibility
  • Field calibratable to reduce costly downtime
  • 4 to 20 mA and voltage outputs in 1 unit for greater versatility

Applications

  • Controlling HVAC/R in Response to Occupancy, Save Energy by Providing Ventilation Only as Required
  • Improving Tenant Comfort
  • Schools, Museums, Airports, Commercial Buildings, etc.
  • OEM Applications
  • Home Automation
  • Big-Box Retail
  • Restaurants
  • C-Stores

Veris CWVS1XX1 Specifications

Input Power 20 to 30 VDC, 24 VAC
Analog Output #1 4 to 20 mA (clipped and capped) or 0 to 3 VDC/0 to 5 VDC/0 to 10 VDC (jumper selectable)
Analog Output #2 4 to 20 mA (clipped and capped) or 0 to 3 VDC/0 to 5 VDC/0 to 10 VDC (jumper selectable)
Sensor Current Draw 200 mA maximum
Operating Humidity Range 0 to 95% RH (non-condensing)
Operating Temperature Range 32 to 122°F (0 to 50°C)
Housing Material High-impact ABS plastic
Relay Contacts (Optional) Form C (SPDT) 1 A at 30 VDC, resistive; 30 W max
Sensor Type Non-dispersive infrared (NDIR), diffusion sampling
Measurement Range 0 to 2,000 ppm
Accuracy ±40 ppm ±8.5% of measured value
Repeatability ±30 ppm ±4.5% of measured value
Response Time About 60 seconds for 90% step change
Click here for complete specifications on the Veris CWVS1XX1

What's included with the Veris CWVS1XX1

  • Veris CWVS1XX1 Wall CO2 Sensor, dual analog output

Ask a question about Veris CWVS1XX1 Wall CO2 Sensor, dual analog output

Customer Reviews for the Veris CWVS1XX1

Veris CWVS1XX1 Offers

The wall CO₂ sensor with dual analog output is a non-dispersive infrared analyzer designed for measuring CO₂ concentration in office and living spaces.

Features

  • Non-dispersive infrared technology repeatable to ±30 ppm ±4.5% of measured value
  • Innovative self-calibration algorithm easy to maintain
  • 5-year calibration interval (recommended)
  • Improve comfort and facilitate compliance with ASHRAE 62.1-2004 standard for air quality
  • Helps with green branding initiatives
  • Dual analog outputs for added user convenience
  • LED indication for power and error detection reduces time spent troubleshooting
  • Switchable 0 to 3/5/10 V output gives increased flexibility
  • US and European mounting holes provide installation flexibility
  • Field calibratable to reduce costly downtime
  • 4 to 20 mA and voltage outputs in 1 unit for greater versatility

Applications

  • Controlling HVAC/R in Response to Occupancy, Save Energy by Providing Ventilation Only as Required
  • Improving Tenant Comfort
  • Schools, Museums, Airports, Commercial Buildings, etc.
  • OEM Applications
  • Home Automation
  • Big-Box Retail
  • Restaurants
  • C-Stores

Veris CWVS1XX1 Specifications

Input Power 20 to 30 VDC, 24 VAC
Analog Output #1 4 to 20 mA (clipped and capped) or 0 to 3 VDC/0 to 5 VDC/0 to 10 VDC (jumper selectable)
Analog Output #2 4 to 20 mA (clipped and capped) or 0 to 3 VDC/0 to 5 VDC/0 to 10 VDC (jumper selectable)
Sensor Current Draw 200 mA maximum
Operating Humidity Range 0 to 95% RH (non-condensing)
Operating Temperature Range 32 to 122°F (0 to 50°C)
Housing Material High-impact ABS plastic
Relay Contacts (Optional) Form C (SPDT) 1 A at 30 VDC, resistive; 30 W max
Sensor Type Non-dispersive infrared (NDIR), diffusion sampling
Measurement Range 0 to 2,000 ppm
Accuracy ±40 ppm ±8.5% of measured value
Repeatability ±30 ppm ±4.5% of measured value
Response Time About 60 seconds for 90% step change