Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Model: E34A14

Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Model: E34A14

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 14 x 3-phase meters.

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 14 x 3-phase meters.

Sale Price $2660.84 USD
Regular Price $2973.00 USD
Availability 2 to 3 Weeks
Quantity

Veris E34A14 Offers

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 14 x 3-phase meters.

Features

  • ANSI and IEC Class 0.5% accuracy, ideal for tenant billing
  • Low equipment and installation cost per metering points
  • Possibility to assign measurement channels as needed for the site: each channel can be assigned to a 3-phase, 2-phase or single-phase meter
  • (4) 3-phase meter E34 can be a (4) 3-phase meter, (8) 2-phase meter, (12) single-phase or any mix, like (1) 3-phase with neutral + (1) 3-phase + (2) 2-phase + (1) 1-phase meters which amounts to 12 channels equivalent to (4) 3-phase meters
  • Low-voltage current transformers (CTs) offer a safer and more accurate alternative to 5 A CTs and shorting blocks
  • Communications: E34A models use Modbus RTU to interface with the majority of Energy and Building Management Systems (EMS, BMS)

Applications

  • Commercial and Residential Sub-Tenant Billing
  • Multi-Dwelling Units
  • Load-Based Cost Allocation
  • Overload Protection
  • Energy Management

Veris E34A14 Specifications

Measurement Voltage 90 to 300 VAC line-to-neutral, 50/60 Hz
Control Power 90 to 277 VAC line-to-neutral, 50/60 Hz, 8 VA
Power/Energy IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Current ±0.5% of reading from 2 to 100% full scale
Sampling Frequency 2,560 Hz
Update Rate 2 seconds (both panels)
Overload Capability 22 kAIC
Physical Interface DIP switch-selectable: 2-wire or 4-wire, RS-485
Protocols Supported Modbus RTU
Address: DIP switch-selectable address: 1 to 247 (in pairs of 2)
Baud Rate DIP switch-selectable: 9600, 19200, 38400
Parity DIP switch-selectable: NONE, ODD, EVEN
Removable Connectors 4.4 to 5.3 in-lb (0.5 to 0.6 N-m)
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Altitude of Operation 9,842.5' (3,000 m)
Mounting Location Indoor use, dry location
Warranty 5 years limited
Agency Approvals UL508 open type device, IEC/EN61010-1
Installation Category Cat III, pollution degree 2
Click here for complete specifications on the Veris E34A14

What's included with the Veris E34A14

  • Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Ask a question about Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Customer Reviews for the Veris E34A14

Veris E34A14 Offers

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 14 x 3-phase meters.

Features

  • ANSI and IEC Class 0.5% accuracy, ideal for tenant billing
  • Low equipment and installation cost per metering points
  • Possibility to assign measurement channels as needed for the site: each channel can be assigned to a 3-phase, 2-phase or single-phase meter
  • (4) 3-phase meter E34 can be a (4) 3-phase meter, (8) 2-phase meter, (12) single-phase or any mix, like (1) 3-phase with neutral + (1) 3-phase + (2) 2-phase + (1) 1-phase meters which amounts to 12 channels equivalent to (4) 3-phase meters
  • Low-voltage current transformers (CTs) offer a safer and more accurate alternative to 5 A CTs and shorting blocks
  • Communications: E34A models use Modbus RTU to interface with the majority of Energy and Building Management Systems (EMS, BMS)

Applications

  • Commercial and Residential Sub-Tenant Billing
  • Multi-Dwelling Units
  • Load-Based Cost Allocation
  • Overload Protection
  • Energy Management

Veris E34A14 Specifications

Measurement Voltage 90 to 300 VAC line-to-neutral, 50/60 Hz
Control Power 90 to 277 VAC line-to-neutral, 50/60 Hz, 8 VA
Power/Energy IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Current ±0.5% of reading from 2 to 100% full scale
Sampling Frequency 2,560 Hz
Update Rate 2 seconds (both panels)
Overload Capability 22 kAIC
Physical Interface DIP switch-selectable: 2-wire or 4-wire, RS-485
Protocols Supported Modbus RTU
Address: DIP switch-selectable address: 1 to 247 (in pairs of 2)
Baud Rate DIP switch-selectable: 9600, 19200, 38400
Parity DIP switch-selectable: NONE, ODD, EVEN
Removable Connectors 4.4 to 5.3 in-lb (0.5 to 0.6 N-m)
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Altitude of Operation 9,842.5' (3,000 m)
Mounting Location Indoor use, dry location
Warranty 5 years limited
Agency Approvals UL508 open type device, IEC/EN61010-1
Installation Category Cat III, pollution degree 2
Click here for complete specifications on the Veris E34A14

What's included with the Veris E34A14

  • Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Ask a question about Veris E34A14 Multi-Circuit/Multi-Circuit Meter, Modbus RTU only, 14 x 3-phase meters

Customer Reviews for the Veris E34A14

More Veris Products

Calibration Lab