This network integration Modbus display panel mount has easy keypad setup.
This network integration Modbus display panel mount has easy keypad setup.
The Modbus network display shows Modbus data. It's available without the box for fast mounting to a panel.
Features
Applications
AC Power Source | 120 VAC 50/60 Hz, line-to-neutral; internal fuse |
Fuse Ratings | 200 mA at 250 5 x 20 mm Fast-Blow |
AC Power Voltage Tolerance | (90 to 132 VAC) for 120 V |
AC Power Frequency | 50/60 Hz |
AC Power Termination | 2-position Euro-style pluggable connector (max wire size 12 gauge) |
Alternate DC Power Source | 12 VDC, 300 mA external current limiting required (auxiliary input disabled if line connected) |
Terminal Block Torque | 4.9 in-lb (0.56 N-m) |
Operating Temperature Range | 32 to 122°F (0 to 50°C); <95% RH non-condensing; indoor use only |
Storage Temperature Range | -4 to 158°F (-20 to 70°C) |
Interface | Downstream: RS-485; upstream: RS-485, RS-232 |
Protocol | Modbus RTU |
Baud Rate | UI-selectable: 2400, 4800, 9600, 19200 |
Parity | UI-selectable: NONE, ODD, EVEN |
Communication Format | 8 data bits, 1 start bit, 1 stop bit |
RS-485 | 1/4 load transceivers; duplex is UI-selectable: 2-wire or 4-wire; 5-position Euro-style pluggable connector |
RS-232 (Upstream Only) | DCE, no handshaking; DB-9 connection; pin 2: transmitted data from display; pin 3: received data to display; pin 5: ground |
Terminal Block Torque | 4.4 in-lb (0.5 N-m) |
Number/Function | 4 (METER, UP, DOWN, SELECT) |
Type | Contact closure or pull-to-ground (10 mA max) |
Isolation | Optical to 2,500 VAC |
Sense | UI-selectable: N.O. or N.C. (i.e. closed = alarm or open = alarm) |
Terminal Block Torque | 3.5 to 4.4 in-lb (0.4 to 0.5 N-m) |
Size | 1 x 4" (2.54 x 10.2 cm) visible area, 2 lines x 16 characters per line |
Backlight | Green, UI-adjustable brightness in 10 steps |
Status (Tri-Color LED) | Green = normal operation; yellow = warning; red = alarm |
Warranty | 5 years limited |
AC Power Source | 120 VAC 50/60 Hz, line-to-neutral; internal fuse |
Fuse Ratings | 200 mA at 250 5 x 20 mm Fast-Blow |
AC Power Voltage Tolerance | (90 to 132 VAC) for 120 V |
AC Power Frequency | 50/60 Hz |
AC Power Termination | 2-position Euro-style pluggable connector (max wire size 12 gauge) |
Alternate DC Power Source | 12 VDC, 300 mA external current limiting required (auxiliary input disabled if line connected) |
Terminal Block Torque | 4.9 in-lb (0.56 N-m) |
Operating Temperature Range | 32 to 122°F (0 to 50°C); <95% RH non-condensing; indoor use only |
Storage Temperature Range | -4 to 158°F (-20 to 70°C) |
Interface | Downstream: RS-485; upstream: RS-485, RS-232 |
Protocol | Modbus RTU |
Baud Rate | UI-selectable: 2400, 4800, 9600, 19200 |
Parity | UI-selectable: NONE, ODD, EVEN |
Communication Format | 8 data bits, 1 start bit, 1 stop bit |
RS-485 | 1/4 load transceivers; duplex is UI-selectable: 2-wire or 4-wire; 5-position Euro-style pluggable connector |
RS-232 (Upstream Only) | DCE, no handshaking; DB-9 connection; pin 2: transmitted data from display; pin 3: received data to display; pin 5: ground |
Terminal Block Torque | 4.4 in-lb (0.5 N-m) |
Number/Function | 4 (METER, UP, DOWN, SELECT) |
Type | Contact closure or pull-to-ground (10 mA max) |
Isolation | Optical to 2,500 VAC |
Sense | UI-selectable: N.O. or N.C. (i.e. closed = alarm or open = alarm) |
Terminal Block Torque | 3.5 to 4.4 in-lb (0.4 to 0.5 N-m) |
Size | 1 x 4" (2.54 x 10.2 cm) visible area, 2 lines x 16 characters per line |
Backlight | Green, UI-adjustable brightness in 10 steps |
Status (Tri-Color LED) | Green = normal operation; yellow = warning; red = alarm |
Warranty | 5 years limited |