Compact, this general purpose transmitter is made of stainless steel and has a ceramic sensor, and features a range of 0 to 25 psi.
Compact, this general purpose transmitter is made of stainless steel and has a ceramic sensor, and features a range of 0 to 25 psi.
Features
Applications
Range | 0 to 25 psi |
Over-Pressure | 58 psi |
Burst Pressure | 102 psi |
Output Signal | Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC Optional 3-wire: 0 to 10 V / Vs = 14-30 V DC Optional 3-wire ratiometric: Vsig = 0.5-4.5 Vs / Vs = 5 ±0.5 V DC |
Accuracy | ±0.5% FSO |
Permissible Load | 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ω 3-wire: Rmin = 10 kΩ |
Influence Effects | Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kΩ |
Response Time | 2-wire: <10 ms 3-wire: <3 ms |
Measuring Rate | 1 kHz |
Thermal Error | <±0.5% FSO / 10K |
Permissible Temperatures | Medium: -13 to 257°F (-25 to 125°C) Electronics environment: -13 to 185°F (-25 to 85°C) Storage: -40 to 185°F (-40 to 85°C) |
Short-circuit Protection | Permanent 3-wire ratiometric: None |
Reverse Polarity Protection | No damage. No function. |
Electromagnetic Protection | Emission and immunity according to EN 61326 |
Stability | Vibration: 10 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6 Shock: 500 g / 1 ms according to DIN EN 60068-2-27 |
Pollution Degree | 4, electrical equipment for outdoor use |
Pressure Port / Housing | 304 SS |
Current Consumption | 2-wire: 25 mA max 3-wire voltage: 5 mA (short-circuit current 20 mA) 3-wire ratiometric: 1.5 mA |
Long-term Stability | <±0.3% FSO/year at reference conditions |
Operation Life | >100 x 106 cycles |
Wetted Parts | Seals: FKM Diaphragm: Ceramic AI2 O3 96% |
CE Conformity | EMC directive: 2004/108/EC Pressure equipment directive: 97/23/EC (module A) Valid for devices with max permissible overpressure <3000 psi |
Weight | 0.2 lbs (120 g) |
Range | 0 to 25 psi |
Over-Pressure | 58 psi |
Burst Pressure | 102 psi |
Output Signal | Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC Optional 3-wire: 0 to 10 V / Vs = 14-30 V DC Optional 3-wire ratiometric: Vsig = 0.5-4.5 Vs / Vs = 5 ±0.5 V DC |
Accuracy | ±0.5% FSO |
Permissible Load | 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ω 3-wire: Rmin = 10 kΩ |
Influence Effects | Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kΩ |
Response Time | 2-wire: <10 ms 3-wire: <3 ms |
Measuring Rate | 1 kHz |
Thermal Error | <±0.5% FSO / 10K |
Permissible Temperatures | Medium: -13 to 257°F (-25 to 125°C) Electronics environment: -13 to 185°F (-25 to 85°C) Storage: -40 to 185°F (-40 to 85°C) |
Short-circuit Protection | Permanent 3-wire ratiometric: None |
Reverse Polarity Protection | No damage. No function. |
Electromagnetic Protection | Emission and immunity according to EN 61326 |
Stability | Vibration: 10 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6 Shock: 500 g / 1 ms according to DIN EN 60068-2-27 |
Pollution Degree | 4, electrical equipment for outdoor use |
Pressure Port / Housing | 304 SS |
Current Consumption | 2-wire: 25 mA max 3-wire voltage: 5 mA (short-circuit current 20 mA) 3-wire ratiometric: 1.5 mA |
Long-term Stability | <±0.3% FSO/year at reference conditions |
Operation Life | >100 x 106 cycles |
Wetted Parts | Seals: FKM Diaphragm: Ceramic AI2 O3 96% |
CE Conformity | EMC directive: 2004/108/EC Pressure equipment directive: 97/23/EC (module A) Valid for devices with max permissible overpressure <3000 psi |
Weight | 0.2 lbs (120 g) |