Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

Model: ACUVIM-EL-M-MV-P1V4

Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

Model: ACUVIM-EL-M-MV-P1V4

Ideal for various standard metering projects, this multifunction power meter with energy class 0.2 harmonics up to 63rd provides real-time, true-RMS measurements of current, power, voltage, energy, and many other parameters. In addition, it has an AcuCT-Flex input, a 100 to 415 V AC power supply, and a DIN rail mount.

Ideal for various standard metering projects, this multifunction power meter with energy class 0.2 harmonics up to 63rd provides real-time, true-RMS measurements of current, power, voltage, energy, and many other parameters. In addition, it has an AcuCT-Flex input, a 100 to 415 V AC power supply, and a DIN rail mount.

Sale Price $455.40 USD
Regular Price $495.00 USD
Availability 2 to 3 Weeks
Quantity

Accuenergy ACUVIM-EL-M-MV-P1V4 Offers

Capable of being configured as either a panel-mount device, as a DIN rail mount transducer, or installed in a pre-configured, pre-wired AcuPanel, this multifunction power and energy meter is ideal for extreme protection in even the toughest application environments.

Features

  • Revenue grade: ANSI C12.20 class 0.2 & IEC62053-22 class 0.2s
  • 4th CT input - Measure neutral current
  • Dual Ethernet ports with both RSTP bridge daisy-chain mode and separately configurable network
  • Dual source meter to monitor energy usage from separate energy sources
  • Data logging: Available in 8 MB onboard and offers three, assignable historical logs and a real time clock to record metering parameters with accurate timestamping (memory expandable to 8 GB with an adjustable log size)
  • Designed with industry leading cybersecurity
  • Modbus-RTU & BACnet MS/ TP ready
  • Data logging: Offers three, assignable historical logs and a real time clock to record many metering parameters with accurate timestamping
  • Individual channel configuration: Can operate as a four channel multi-circuit meter and allow CT wiring configuration through remote channel mapping
  • Automatic frequency adaptation: Adjusts to local frequencies, such as 50 or 60 Hz, making it ideal in countries with differing electrical frequencies

Communication

  • Modbus RTU Protocol and BACnet MS/TP via RS485
  • Wi-Fi and Ethernet Communication Channels (Modbus TCP, BACnet IP, HTTP, SMTP, SNTP, HTTPs, Post, FTP)
  • PROFIBUS DP
  • Dual RS485 communication ports
  • Time of use

  • Users can assign up to four tariffs (sharp, peak, valley, and normal) to different time periods within a day
  • This meter will calculate and accumulate energy to different tariffs according to the meter's internal clock and TOU settings
  • Display

  • Clear, large character LCD with white backlight
  • Wide environmental temperature endurance
  • View load percentage, four quadrant powers, and load nature
  • Alarms

  • Configure up to 16 indicated alarm set at specified time intervals
  • Parameters that are over or under setting limit and persist longer than the specified time interval will be recorded and trigger the Alarm DO
  • Choose from 80 available parameters
  • Power quality monitoring

  • Safeguard your electrical equipment from harmonic distortion, voltage sag and swells and frequency variations
  • Use the harmonic content data to diagnose and prevent power quality issues before a system wide failure occurs or to improve efficiencies
  • Monitor individual harmonics voltage and current
  • View real-time power quality information, like harmonic content and unbalance factor
  • Record up to 16 PQ events with timestamp and trigger conditions
  • Rugged, panel-mount design

  • Designed for high-performance in power distribution or plant automation applications
  • High tolerance for temperature fluctuations and harsh installations
  • IP56 rating (front)
  • Meets DIN 43700 or ANSI C39.1 round outline standards
  • Applications

    • Power distribution automation
    • Medium and low voltage systems
    • Industrial automation
    • Energy management systems
    • Power quality analysis
    • Electric switch gear and control panels
    • Building automation
    • Marine applications

    Accuenergy ACUVIM-EL-M-MV-P1V4 Specifications

    Current Inputs (Each Channel) Nominal current options:
    1: 5 A
    2: 1 A
    3: 1 A (333 mV)
    4: 1 A (100 mV Rope CT)

    Metering range:
    1: 0 to 10 A
    2: 0 to 2 A
    3: 0 to 1.2 A
    4: 0 to 1.2 A

    Pickup current:
    1: 5 mA
    2: 1 mA
    3: 5 mA
    4: 5 mA

    Withstand:
    20 Arms continuous, 0.1% of nominal
    100 Arms for 1 second, non-recurring

    Burden: 0.05 V A (typical) at 5 A RMS

    Accuracy: 0.1% at reading
    Voltage Inputs (Each Channel) Nominal full scale: 400 V AC L-N, 690 V AC L-L (+20%)
    Withstand: 1500 V AC continuous; 2500 V AC, 50/60 Hz for 1 minute
    Input impedance: 2 MΩ per phase
    Metering frequency: 45 to 65 Hz, 300 to 500 Hz
    Pickup voltage: 10 V AC
    Accuracy: 0.1% at reading
    Energy Accuracy Active: Class 0.2s (IEC 62053-22), Class 0.2s (ANSI C12.20)
    Reactive: Class 0.5 (IEC62053-24)
    Harmonic Resolution Metered value: 2nd to 63rd Harmonic (50 or 60 Hz type)
    Communications Modbus-RTU or BACnet MS/TP: Modbus-RTU
    2-wire shielded twisted pair cable connection 1200 to 115,200 bps
    Control Power Universal: AC or DC

    Operating Range: 100 to 415 V AC, 50/60 Hz; 100 to 300 V DC
    Burden: 5 W
    Frequency: 50/60 Hz
    Withstand: 3250 V AC, 50/60 Hz for 1 minute
    Installation Category III (Distribution)
    Power Supply: 100 to 415 V AC, 50/60 Hz, 100 to 300 V DC
    Consumption: 3 W
    Environmental Conditions Operating temperature: -13 to 158°F (-25 to 70°C)
    Storage temperature: -40 to 176°F (-40 to 85°C)
    Relative humidity: 5 to 95% non-condensing
    Protection Level IP56 (front), IP30 (cover)
    Standard Compliance and Certifications Measurement standard: IEC 62053-22, ANSI C12.20, IEC61557-12
    Environmental standard: IEC 60068-2, CE, RoHS
    Safety standard: IEC 61010-1, UL 61010-1
    EMC standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4
    Outlines standard: DIN 43700, ANSI C39.1
    Protocol conformance: IEC 61850 2nd Edition
    Dimensions 3.8 x 3.8 x 2" (96 x 96 x 50.7 mm)
    Cut-out: 3.62 x 3.62" (92 x 92 mm) or 4" (102 mm) round
    Weight 0.77 lbs (350 g)
    Click here for complete specifications on the Accuenergy ACUVIM-EL-M-MV-P1V4

    What's included with the Accuenergy ACUVIM-EL-M-MV-P1V4

    • Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

    Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC.

    Accuenergy AXM-DIN Rail Mounting Adapter for the Acuvim II/Acuvim IIBN/Acuvim L, 1.37" DIN AXM-DIN
    Compatible with the Acuvim II, Acuvim IIBN, and Acuvim-L series energy meters, this rail mounting adapter allows for easy installation on either a horizontal or vertical DIN rail mount.




    MODBUS RS485 to USB Adapter USB-RS485
    MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC.




    Accuenergy IP66/NEMA4X Protection Cover for the Acuvim II/Acuvim-L, 4.21 x 4.21" 96-IP66
    Compatible with 96 x 96 meters, this screen protector is an accessory or replacement part.




    Ask a question about Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

    Customer Reviews for the Accuenergy ACUVIM-EL-M-MV-P1V4

    Accuenergy ACUVIM-EL-M-MV-P1V4 Offers

    Capable of being configured as either a panel-mount device, as a DIN rail mount transducer, or installed in a pre-configured, pre-wired AcuPanel, this multifunction power and energy meter is ideal for extreme protection in even the toughest application environments.

    Features

    • Revenue grade: ANSI C12.20 class 0.2 & IEC62053-22 class 0.2s
    • 4th CT input - Measure neutral current
    • Dual Ethernet ports with both RSTP bridge daisy-chain mode and separately configurable network
    • Dual source meter to monitor energy usage from separate energy sources
    • Data logging: Available in 8 MB onboard and offers three, assignable historical logs and a real time clock to record metering parameters with accurate timestamping (memory expandable to 8 GB with an adjustable log size)
    • Designed with industry leading cybersecurity
    • Modbus-RTU & BACnet MS/ TP ready
    • Data logging: Offers three, assignable historical logs and a real time clock to record many metering parameters with accurate timestamping
    • Individual channel configuration: Can operate as a four channel multi-circuit meter and allow CT wiring configuration through remote channel mapping
    • Automatic frequency adaptation: Adjusts to local frequencies, such as 50 or 60 Hz, making it ideal in countries with differing electrical frequencies

    Communication

  • Modbus RTU Protocol and BACnet MS/TP via RS485
  • Wi-Fi and Ethernet Communication Channels (Modbus TCP, BACnet IP, HTTP, SMTP, SNTP, HTTPs, Post, FTP)
  • PROFIBUS DP
  • Dual RS485 communication ports
  • Time of use

  • Users can assign up to four tariffs (sharp, peak, valley, and normal) to different time periods within a day
  • This meter will calculate and accumulate energy to different tariffs according to the meter's internal clock and TOU settings
  • Display

  • Clear, large character LCD with white backlight
  • Wide environmental temperature endurance
  • View load percentage, four quadrant powers, and load nature
  • Alarms

  • Configure up to 16 indicated alarm set at specified time intervals
  • Parameters that are over or under setting limit and persist longer than the specified time interval will be recorded and trigger the Alarm DO
  • Choose from 80 available parameters
  • Power quality monitoring

  • Safeguard your electrical equipment from harmonic distortion, voltage sag and swells and frequency variations
  • Use the harmonic content data to diagnose and prevent power quality issues before a system wide failure occurs or to improve efficiencies
  • Monitor individual harmonics voltage and current
  • View real-time power quality information, like harmonic content and unbalance factor
  • Record up to 16 PQ events with timestamp and trigger conditions
  • Rugged, panel-mount design

  • Designed for high-performance in power distribution or plant automation applications
  • High tolerance for temperature fluctuations and harsh installations
  • IP56 rating (front)
  • Meets DIN 43700 or ANSI C39.1 round outline standards
  • Applications

    • Power distribution automation
    • Medium and low voltage systems
    • Industrial automation
    • Energy management systems
    • Power quality analysis
    • Electric switch gear and control panels
    • Building automation
    • Marine applications

    Accuenergy ACUVIM-EL-M-MV-P1V4 Specifications

    Current Inputs (Each Channel) Nominal current options:
    1: 5 A
    2: 1 A
    3: 1 A (333 mV)
    4: 1 A (100 mV Rope CT)

    Metering range:
    1: 0 to 10 A
    2: 0 to 2 A
    3: 0 to 1.2 A
    4: 0 to 1.2 A

    Pickup current:
    1: 5 mA
    2: 1 mA
    3: 5 mA
    4: 5 mA

    Withstand:
    20 Arms continuous, 0.1% of nominal
    100 Arms for 1 second, non-recurring

    Burden: 0.05 V A (typical) at 5 A RMS

    Accuracy: 0.1% at reading
    Voltage Inputs (Each Channel) Nominal full scale: 400 V AC L-N, 690 V AC L-L (+20%)
    Withstand: 1500 V AC continuous; 2500 V AC, 50/60 Hz for 1 minute
    Input impedance: 2 MΩ per phase
    Metering frequency: 45 to 65 Hz, 300 to 500 Hz
    Pickup voltage: 10 V AC
    Accuracy: 0.1% at reading
    Energy Accuracy Active: Class 0.2s (IEC 62053-22), Class 0.2s (ANSI C12.20)
    Reactive: Class 0.5 (IEC62053-24)
    Harmonic Resolution Metered value: 2nd to 63rd Harmonic (50 or 60 Hz type)
    Communications Modbus-RTU or BACnet MS/TP: Modbus-RTU
    2-wire shielded twisted pair cable connection 1200 to 115,200 bps
    Control Power Universal: AC or DC

    Operating Range: 100 to 415 V AC, 50/60 Hz; 100 to 300 V DC
    Burden: 5 W
    Frequency: 50/60 Hz
    Withstand: 3250 V AC, 50/60 Hz for 1 minute
    Installation Category III (Distribution)
    Power Supply: 100 to 415 V AC, 50/60 Hz, 100 to 300 V DC
    Consumption: 3 W
    Environmental Conditions Operating temperature: -13 to 158°F (-25 to 70°C)
    Storage temperature: -40 to 176°F (-40 to 85°C)
    Relative humidity: 5 to 95% non-condensing
    Protection Level IP56 (front), IP30 (cover)
    Standard Compliance and Certifications Measurement standard: IEC 62053-22, ANSI C12.20, IEC61557-12
    Environmental standard: IEC 60068-2, CE, RoHS
    Safety standard: IEC 61010-1, UL 61010-1
    EMC standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4
    Outlines standard: DIN 43700, ANSI C39.1
    Protocol conformance: IEC 61850 2nd Edition
    Dimensions 3.8 x 3.8 x 2" (96 x 96 x 50.7 mm)
    Cut-out: 3.62 x 3.62" (92 x 92 mm) or 4" (102 mm) round
    Weight 0.77 lbs (350 g)
    Click here for complete specifications on the Accuenergy ACUVIM-EL-M-MV-P1V4

    What's included with the Accuenergy ACUVIM-EL-M-MV-P1V4

    • Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

    Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC.

    Accuenergy AXM-DIN Rail Mounting Adapter for the Acuvim II/Acuvim IIBN/Acuvim L, 1.37" DIN AXM-DIN
    Compatible with the Acuvim II, Acuvim IIBN, and Acuvim-L series energy meters, this rail mounting adapter allows for easy installation on either a horizontal or vertical DIN rail mount.




    MODBUS RS485 to USB Adapter USB-RS485
    MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC.




    Accuenergy IP66/NEMA4X Protection Cover for the Acuvim II/Acuvim-L, 4.21 x 4.21" 96-IP66
    Compatible with 96 x 96 meters, this screen protector is an accessory or replacement part.




    Ask a question about Accuenergy Acuvim-EL Series Multifunction Power Meter with DIN-rail mounting without display, AcuCT-Flex input & 333 mV input, 100 to 415 V AC

    Customer Reviews for the Accuenergy ACUVIM-EL-M-MV-P1V4

    More Accuenergy Products

    Calibration Lab