Work with a robust solution for power monitoring, kWh metering, power quality analysis, and more with these advanced power and energy meters. In addition, these meters are ideal for integration into any project environment, and an array of plug-in expansion modules facilitate communication on over 15 industry protocols.
Work with a robust solution for power monitoring, kWh metering, power quality analysis, and more with these advanced power and energy meters. In addition, these meters are ideal for integration into any project environment, and an array of plug-in expansion modules facilitate communication on over 15 industry protocols.
Features
Applications
Metering | |
Voltage | Accuracy: 0.2% Resolution: 0.1 V Range: 10 V to 1000 kV |
Current | Accuracy: 0.2% Resolution: 0.1 mA Range: 5 mA to 50000 A |
Power | Accuracy: 0.2% Resolution: 1 W Range: -9999 to 9999 MW |
Reactive Power | Accuracy: 0.2% Resolution: 1 var Range: -9999 to 9999 Mvar |
Apparent Power | Accuracy: 0.2% Resolution: 1 VA Range: 0 to 9999 MVA |
Power Demand | Accuracy: 0.2% Resolution: 1 W Range: -9999 to 9999 MW |
Reactive Power Demand | Accuracy: 0.2% Resolution: 1 var Range: -9999 to 9999 Mvar |
Apparent Power Demand | Accuracy: 0.2% Resolution: 1 VA Range: 0 to 9999 MVA |
Power Factor | Accuracy: 0.2% Resolution: 0.001 Range: -1.000 to 1.000 |
Frequency | Accuracy: 0.02% Resolution: 0.01 Hz Range: 45 to 65 Hz (50 or 60 Hz type) 300 Hz to 500 Hz (400 Hz type) |
Energy | Primary accuracy: 0.2%, resolution: 0.1 kWh, Range: 0 to 99999999.9 kWh Secondary accuracy: 0.2%, resolution: 0.001 kWh, Range: 0 to 999999.999 kWh |
Reactive Energy | Primary accuracy: 0.2%, resolution: 0.1 kvarh, range: 0 to 99999999.9 kvarh Secondary accuracy: 0.2%, resolution: 0.001 kvarh, range: 0 to 999999.999 kvarh |
Apparent Energy | Primary accuracy: 0.2%, resolution: 0.1 kVAh, range: 0 to 99999999.9 kVAh Secondary accuracy: 0.2%, resolution: 0.001 kVAh, range: 0 to 999999.999 kVAh |
Harmonics | Accuracy: 1.0% Resolution: 0.1% |
Phase Angle | Accuracy: 2.0% Resolution: 0.1° Range: 0.0° to 359.9° |
Unbalance Factor | Accuracy: 2.0% Resolution: 0.1% Range: 0.0 to 100.0% |
Running Time | Resolution: 0.01 h Range: 0 to 9999999.99 h |
Current Inputs (Each Channel) | |
Nominal Current | 1: 5 A 2: 1 A 3: 1 A (333 mV) 4: 1 A (100 mV Rope-CT) 5: 1 A (80 mA/100 mA/200 mA) |
Metering Range | 1: 0 to 10 A 2: 0 to 2 A 3: 0 to 1.2 A 4: 0 to 1.2 A 5: 0 to 1.2 A |
Pickup Current | 1: 5 mA 2: 1 mA 3: 5 mA 4: 5 mA 5: 5 mA |
Withstand | 20 Arms continuous, 0.1% of nominal 100 Arms for 1 second, non-recurring |
Burden | 0.05 VA (typical) at 5 Arms |
Accuracy | 0.2% full scale |
Voltage Inputs (Each Channel) | |
Nominal Full Scale | 400 V AC L to N, 690 V AC L-L (+20%) |
Withstand | 1500 V AC continuous 2500 V AC, 50/60 Hz for 1 minute |
Input Impedence | 2 MΩ per phase |
Metering Frequency | 45 to 65 Hz, 300 to 500 Hz |
Pickup Voltage | 10 V AC |
Accuracy | 0.2% full scale |
Energy Accuracy | |
Active | Class 0.2 second (according to IEC 62053-22) Class 0.2 second (according to ANSI C12.20) |
Reactive | Class 2 (according to IEC 62053-23) |
Harmonic Resolution | |
Metered Value | 63rd harmonic (50 Hz or 60 Hz type) 15th harmonic (400 Hz type) |
Digital Input | |
Input Voltage | Range: 20 to 160 VAC/DC Current (maximum): 2 mA |
Voltage | Start: 15 V Stop: 5 V |
Pulse Frequency (Maximum) | 100 Hz, 50% duty ratio (5 ms ON and 5 ms OFF) |
SOE Resolution | 2 ms |
Digital Output (DO) (Photo-Mos) | |
Voltage Range | 0 to 250 VAC, 30 VDC |
Load Current | 5 A (R), 2 A (L) |
Output Frequency | 25 Hz, 50% Duty Ratio (20 ms ON, 20 ms OFF) |
Isolation Voltage | 2500 VAC |
Relay Output (RO) | |
Switching Voltage (Maximum) | 250 VAC, 30 VDC |
Load Current | 5 A (R), 2 A (L) |
Set Time | 10 ms (maximum) |
Contact Resistance | 30 mΩ (maximum) |
Isolation Voltage | 2500 VAC |
Mechanical Life | 1.5 x 10&supT; |
Analog Output (AO) | |
Output Range | 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately) |
Accuracy | 0.5% |
Temperature Drift | 50 ppm/°C typical |
Isolation Voltage | 500 VDC |
Open Circuit Voltage | 15 V |
Analog Input (AI) | |
Input Range | 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately) |
Accuracy | 0.5% |
Temperature Drift | 50 ppm/°C typical |
Isolation Voltage | 500 VDC |
Power Supply for DI (24 VDC) | |
Output | Voltage: 24 VDC Current: 42 mA |
Load (Maximum) | 21 Dis |
Operating Environment | |
Temperature | Operation: -13 to 158°F (-25 to 70°C) Storage: -40 to 185°F (-40 to 85°C) |
Relative Humidity | 5 to 95% non-condensing |
Metering | |
Voltage | Accuracy: 0.2% Resolution: 0.1 V Range: 10 V to 1000 kV |
Current | Accuracy: 0.2% Resolution: 0.1 mA Range: 5 mA to 50000 A |
Power | Accuracy: 0.2% Resolution: 1 W Range: -9999 to 9999 MW |
Reactive Power | Accuracy: 0.2% Resolution: 1 var Range: -9999 to 9999 Mvar |
Apparent Power | Accuracy: 0.2% Resolution: 1 VA Range: 0 to 9999 MVA |
Power Demand | Accuracy: 0.2% Resolution: 1 W Range: -9999 to 9999 MW |
Reactive Power Demand | Accuracy: 0.2% Resolution: 1 var Range: -9999 to 9999 Mvar |
Apparent Power Demand | Accuracy: 0.2% Resolution: 1 VA Range: 0 to 9999 MVA |
Power Factor | Accuracy: 0.2% Resolution: 0.001 Range: -1.000 to 1.000 |
Frequency | Accuracy: 0.02% Resolution: 0.01 Hz Range: 45 to 65 Hz (50 or 60 Hz type) 300 Hz to 500 Hz (400 Hz type) |
Energy | Primary accuracy: 0.2%, resolution: 0.1 kWh, Range: 0 to 99999999.9 kWh Secondary accuracy: 0.2%, resolution: 0.001 kWh, Range: 0 to 999999.999 kWh |
Reactive Energy | Primary accuracy: 0.2%, resolution: 0.1 kvarh, range: 0 to 99999999.9 kvarh Secondary accuracy: 0.2%, resolution: 0.001 kvarh, range: 0 to 999999.999 kvarh |
Apparent Energy | Primary accuracy: 0.2%, resolution: 0.1 kVAh, range: 0 to 99999999.9 kVAh Secondary accuracy: 0.2%, resolution: 0.001 kVAh, range: 0 to 999999.999 kVAh |
Harmonics | Accuracy: 1.0% Resolution: 0.1% |
Phase Angle | Accuracy: 2.0% Resolution: 0.1° Range: 0.0° to 359.9° |
Unbalance Factor | Accuracy: 2.0% Resolution: 0.1% Range: 0.0 to 100.0% |
Running Time | Resolution: 0.01 h Range: 0 to 9999999.99 h |
Current Inputs (Each Channel) | |
Nominal Current | 1: 5 A 2: 1 A 3: 1 A (333 mV) 4: 1 A (100 mV Rope-CT) 5: 1 A (80 mA/100 mA/200 mA) |
Metering Range | 1: 0 to 10 A 2: 0 to 2 A 3: 0 to 1.2 A 4: 0 to 1.2 A 5: 0 to 1.2 A |
Pickup Current | 1: 5 mA 2: 1 mA 3: 5 mA 4: 5 mA 5: 5 mA |
Withstand | 20 Arms continuous, 0.1% of nominal 100 Arms for 1 second, non-recurring |
Burden | 0.05 VA (typical) at 5 Arms |
Accuracy | 0.2% full scale |
Voltage Inputs (Each Channel) | |
Nominal Full Scale | 400 V AC L to N, 690 V AC L-L (+20%) |
Withstand | 1500 V AC continuous 2500 V AC, 50/60 Hz for 1 minute |
Input Impedence | 2 MΩ per phase |
Metering Frequency | 45 to 65 Hz, 300 to 500 Hz |
Pickup Voltage | 10 V AC |
Accuracy | 0.2% full scale |
Energy Accuracy | |
Active | Class 0.2 second (according to IEC 62053-22) Class 0.2 second (according to ANSI C12.20) |
Reactive | Class 2 (according to IEC 62053-23) |
Harmonic Resolution | |
Metered Value | 63rd harmonic (50 Hz or 60 Hz type) 15th harmonic (400 Hz type) |
Digital Input | |
Input Voltage | Range: 20 to 160 VAC/DC Current (maximum): 2 mA |
Voltage | Start: 15 V Stop: 5 V |
Pulse Frequency (Maximum) | 100 Hz, 50% duty ratio (5 ms ON and 5 ms OFF) |
SOE Resolution | 2 ms |
Digital Output (DO) (Photo-Mos) | |
Voltage Range | 0 to 250 VAC, 30 VDC |
Load Current | 5 A (R), 2 A (L) |
Output Frequency | 25 Hz, 50% Duty Ratio (20 ms ON, 20 ms OFF) |
Isolation Voltage | 2500 VAC |
Relay Output (RO) | |
Switching Voltage (Maximum) | 250 VAC, 30 VDC |
Load Current | 5 A (R), 2 A (L) |
Set Time | 10 ms (maximum) |
Contact Resistance | 30 mΩ (maximum) |
Isolation Voltage | 2500 VAC |
Mechanical Life | 1.5 x 10&supT; |
Analog Output (AO) | |
Output Range | 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately) |
Accuracy | 0.5% |
Temperature Drift | 50 ppm/°C typical |
Isolation Voltage | 500 VDC |
Open Circuit Voltage | 15 V |
Analog Input (AI) | |
Input Range | 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately) |
Accuracy | 0.5% |
Temperature Drift | 50 ppm/°C typical |
Isolation Voltage | 500 VDC |
Power Supply for DI (24 VDC) | |
Output | Voltage: 24 VDC Current: 42 mA |
Load (Maximum) | 21 Dis |
Operating Environment | |
Temperature | Operation: -13 to 158°F (-25 to 70°C) Storage: -40 to 185°F (-40 to 85°C) |
Relative Humidity | 5 to 95% non-condensing |