Ideal for measuring ground impedance on ground rods and bus bars, this ground resistance tester measures without auxiliary rods and is perfect for multi-grounded systems without disconnecting or de-energizing the ground system under test. In addition, this tester features EN 61010-1, 100 V CAT IV, and 150 V CAT III safety standards.
Ideal for measuring ground impedance on ground rods and bus bars, this ground resistance tester measures without auxiliary rods and is perfect for multi-grounded systems without disconnecting or de-energizing the ground system under test. In addition, this tester features EN 61010-1, 100 V CAT IV, and 150 V CAT III safety standards.
Quickly and easily clamp this ground resistance tester around the grounding electrode or conductor and measure the resistance to the ground. By performing measurements on intact ground systems, verify the quality of the grounding connections and bonds. Additionally, measure the resistance and continuity of grounding loops around pads and buildings.
Features
Applications
Ground Resistance Measurement | |
Measurement Range | 0.01 to 0.099 Ω 0.1 to 0.99 Ω 1 to 49.9 Ω 50 to 149 Ω 150 to 245 Ω 250 to 440 Ω 450 to 640 Ω 650 to 1200 Ω |
Resolution | 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 5 Ω 10 Ω 10 Ω 50 Ω |
Accuracy | ±(1.5% reading + 0.01 Ω) ±(1.5% reading + 0.02 Ω) ±(1.5% reading + 0.1 Ω) ±(2.5% reading + 2 Ω) ±(5% reading + 10 Ω) ±(10% reading + 20 Ω) ±(15% reading + 20 Ω) ±(20% reading + 100 Ω) |
Test Frequency | 2083 Hz |
Maximum Overload | Permanent current: 100 maximum, 50/60 Hz; 20 A at 800 Hz |
Current Measurement Range (auto-ranging) | |
Measurement Range | 0.5 to 9.995 mA 10 to 99.9 mA 100 to 299 mA 0.3 to 2.99 A 3 to 20 A |
Resolution | 50 µA 100 µA 1 mA 10 mA 100 mA |
Accuracy | ±(2% reading + 200 µA) ±(2% reading + 100 µA) ±(2% reading + 1 mA) ±(2% reading + 10 mA) ±(2% reading + 100 mA) |
General Specifications | |
Display | OLED, 152 segments, 1.89 x 1.55" (48 x 39 mm) |
Memory | 300 measurements |
Alarm | Two separate alarms (Ω and A) |
Battery | Type: 4 x 1.5 V LR6 (AA) alkaline batteries or 4 x NiMH batteries Life: 12 hours or 1440 30-second tests approximately |
Environmental | Operating temperature: -4 to 131°F (-20 to 55°C) Storage temperature: -22 to 158°F (-30 to 70°C) Relative humidity: Up to 90% at 40°C Ingress protection: IP40 |
EMC | EN 61326-1 |
Safety Compliance | IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 100 V CAT IV |
Dimensions | Jaw opening: 1.26" (32 mm) maximum, 1.18 x 1.57" (30 x 40 mm), or 0.79 x 2.17" (20 x 55 mm) bar Overall: 11.8 x 4.2 x 2.2" (300 x 106 x 56 mm) |
Weight | 2.6 lbs (1.2 kg) with battery |
Click on a category to view a selection of compatible accessories with the AEMC 6418 Ground Resistance Tester, 0.1 to 1200 Ω, 0.5 to 20 A.
Ground Resistance Measurement | |
Measurement Range | 0.01 to 0.099 Ω 0.1 to 0.99 Ω 1 to 49.9 Ω 50 to 149 Ω 150 to 245 Ω 250 to 440 Ω 450 to 640 Ω 650 to 1200 Ω |
Resolution | 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 5 Ω 10 Ω 10 Ω 50 Ω |
Accuracy | ±(1.5% reading + 0.01 Ω) ±(1.5% reading + 0.02 Ω) ±(1.5% reading + 0.1 Ω) ±(2.5% reading + 2 Ω) ±(5% reading + 10 Ω) ±(10% reading + 20 Ω) ±(15% reading + 20 Ω) ±(20% reading + 100 Ω) |
Test Frequency | 2083 Hz |
Maximum Overload | Permanent current: 100 maximum, 50/60 Hz; 20 A at 800 Hz |
Current Measurement Range (auto-ranging) | |
Measurement Range | 0.5 to 9.995 mA 10 to 99.9 mA 100 to 299 mA 0.3 to 2.99 A 3 to 20 A |
Resolution | 50 µA 100 µA 1 mA 10 mA 100 mA |
Accuracy | ±(2% reading + 200 µA) ±(2% reading + 100 µA) ±(2% reading + 1 mA) ±(2% reading + 10 mA) ±(2% reading + 100 mA) |
General Specifications | |
Display | OLED, 152 segments, 1.89 x 1.55" (48 x 39 mm) |
Memory | 300 measurements |
Alarm | Two separate alarms (Ω and A) |
Battery | Type: 4 x 1.5 V LR6 (AA) alkaline batteries or 4 x NiMH batteries Life: 12 hours or 1440 30-second tests approximately |
Environmental | Operating temperature: -4 to 131°F (-20 to 55°C) Storage temperature: -22 to 158°F (-30 to 70°C) Relative humidity: Up to 90% at 40°C Ingress protection: IP40 |
EMC | EN 61326-1 |
Safety Compliance | IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 100 V CAT IV |
Dimensions | Jaw opening: 1.26" (32 mm) maximum, 1.18 x 1.57" (30 x 40 mm), or 0.79 x 2.17" (20 x 55 mm) bar Overall: 11.8 x 4.2 x 2.2" (300 x 106 x 56 mm) |
Weight | 2.6 lbs (1.2 kg) with battery |
Click on a category to view a selection of compatible accessories with the AEMC 6418 Ground Resistance Tester, 0.1 to 1200 Ω, 0.5 to 20 A.