Fluke Networks 19800HD9 TS19 Test Set

Model: 19800HD9 | UPC: 754082038344

Fluke Networks 19800HD9 TS19 Test Set

Model: 19800HD9 | UPC: 754082038344

Complete with a rugged design, this telephone test set is a professional made for testing data lines. Accidental disruption of service can be avoided while testing data lines with the DataSafe feature while on monitor mode.

Complete with a rugged design, this telephone test set is a professional made for testing data lines. Accidental disruption of service can be avoided while testing data lines with the DataSafe feature while on monitor mode.

Sale Price $166.24 USD
Regular Price $174.99 USD
Availability 2 to 3 Weeks
Quantity

Fluke Networks 19800HD9 Offers

Features

  • High impedance DataSafeTM operation in monitor mode
  • Tone (DTMF) and pulse operation
  • Last number redial
  • Polarity indication in talk mode

Fluke Networks 19800HD9 Specifications

Electrical Specifications
Over-Voltage Protection Protected against over-voltages to 300 V
Transient Voltage Protection Protected against transient voltages to 1500 V
Loop Limit 2.4 kΩ maximum at 48 VDC (nominal 15 mA minimum loop current)
DC Resistance (Talk Mode) 150 Ω typical at 80 mA current
AC Impedance (Monitor Mode) Low impedance (Ring position) 600Ω at 1 KHz typical
High impedance (HI Z position) 100 k&937; minimum at 1 KHz
Rotary Dial Output Pulsing Rate: 10 pps +0.5 pps
Percent Break: 10 pps +0.5 pps
Interdigit: 800 ms typical
Leakage During Break: > 50 k&3937;
DTMF Output Tone Frequency: ±1% maximum
Level per Tone Pair: +2 dBm maximum, -8 dBm minimum
High versus Low Tone Difference: 4 dB maximum
Maximum Sound Level from Speaker 125 dB(A) above 20 μPa for less than 1 second
General Specifications
Temperature Operating: 23 to 104°F (-5 to 40°C)
Storage: -40 to 150.8°F (-40 to 66°C)
Altitude To 3,000 m (10,000 ft) maximum
Dimensions 8.75 x 2.375 x 3.375" (22.2 x 6.03 x 8.57 cm)
Weight 10.8 oz (0.3 kg)
Safety IEC 61010-1:2010, Pollution Degree 2, Category: None complies with CAN/CSA-C22.2 No. 61010-1

What's included with the Fluke Networks 19800HD9

  • Fluke Networks 19800HD9 TS19 Test Set

Ask a question about Fluke Networks 19800HD9 TS19 Test Set

Customer Reviews for the Fluke Networks 19800HD9

Fluke Networks 19800HD9 Offers

Features

  • High impedance DataSafeTM operation in monitor mode
  • Tone (DTMF) and pulse operation
  • Last number redial
  • Polarity indication in talk mode

Fluke Networks 19800HD9 Specifications

Electrical Specifications
Over-Voltage Protection Protected against over-voltages to 300 V
Transient Voltage Protection Protected against transient voltages to 1500 V
Loop Limit 2.4 kΩ maximum at 48 VDC (nominal 15 mA minimum loop current)
DC Resistance (Talk Mode) 150 Ω typical at 80 mA current
AC Impedance (Monitor Mode) Low impedance (Ring position) 600Ω at 1 KHz typical
High impedance (HI Z position) 100 k&937; minimum at 1 KHz
Rotary Dial Output Pulsing Rate: 10 pps +0.5 pps
Percent Break: 10 pps +0.5 pps
Interdigit: 800 ms typical
Leakage During Break: > 50 k&3937;
DTMF Output Tone Frequency: ±1% maximum
Level per Tone Pair: +2 dBm maximum, -8 dBm minimum
High versus Low Tone Difference: 4 dB maximum
Maximum Sound Level from Speaker 125 dB(A) above 20 μPa for less than 1 second
General Specifications
Temperature Operating: 23 to 104°F (-5 to 40°C)
Storage: -40 to 150.8°F (-40 to 66°C)
Altitude To 3,000 m (10,000 ft) maximum
Dimensions 8.75 x 2.375 x 3.375" (22.2 x 6.03 x 8.57 cm)
Weight 10.8 oz (0.3 kg)
Safety IEC 61010-1:2010, Pollution Degree 2, Category: None complies with CAN/CSA-C22.2 No. 61010-1