Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Model: OFP-SM | UPC: 754082093909

Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Model: OFP-SM | UPC: 754082093909

Sale Price $8235.54 USD
Regular Price $8668.99 USD
Availability 4 to 5 Weeks
Quantity
Add Gold Support to your OFP-SM

Choose any one of these options

Clear selected options

Add Gold Support to your OFP-SM

Choose any one of these options

Clear selected options


Fluke Networks OptiFiber Pro OTDR Offers

OptiFiber® Pro is the industry’s first OTDR built from the ground up to meet the challenges of enterprise fiber infrastructures. This troubleshooting and certification tool combines uncomplicated power, unparalleled efficiency and the exact functions needed for troubleshooting campus, data center and storage fiber networks.

The OptiFiber® Pro OTDR elevates fiber testing with the industry’s only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Features

  • Extremely short event and attenuation dead zone
  • Two second trace per wavelength
  • DataCenter OTDR™ mode
  • Graphical EventMap™ view
  • Dynamic project and user profile management
  • On-screen help with corrective actions
  • FiberInspector™ probe

Features


Smartphone User Interface

Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.

Advantages:

  • Single-touch tap and swipe control for selecting and scrolling menu items
  • Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
  • Task-focused design to reduce back and forth navigation through screens
  • Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
  • Context sensitive on-screen help that gives users additional details or problem resolution suggestions

Optimized for the Datacenter

Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.

With a simple one-touch selection, users enter DataCenter OTDR mode - without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters - end-detection algorithms, pulse widths, etc - without getting confused by the short links or number of connectors.

Advantages:

  • Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
  • DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
  • The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

Unique Certification with Fexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project - defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  • Full OTDR capability that certifies fiber performance based on job assignment for each operator
  • Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  • Easy monitoring of job progress with pass/fail results
  • On-screen report generation and upload to LinkWare™ application

Other Key Features

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software
Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

FiberInspector™ probe
OptiFiber Pro’s video inspection system examines patch cords and patch panel bulkheads to avoid the number one cause of fiber link failure – contamination. Significant time is saved because the probe is inserted directly into the patch panel’s bulkhead to examine installed fiber terminations without disassembling the patch panel. Technicians assign a pass or fail grade to the fiber, append a comment and save it for use in certification reports.

Specifications

OTDR Specifications
Multimode module Singlemode module Quad module
Wavelengths 850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic Range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max Distance Range Setting 40 km 130 km MM: 40 km
SM: 130 km
Distance Measurement Range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample Resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse Widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Rime (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
  2. Measured at ± 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.
FiberInspector Probe Specifications
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source TFS mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 x 1.5 in (1175 x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32 to 122°F (0 to 50 °C)
Storage: -4 to 158°F (-20 to 70°C)
Certifications CE (when used with the mainframe)
VFL Specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2
General Specifications
Weight 3lbs, 5 oz (1.28 kg)
Dimensions 2.625 x 5.25 x 11.0 in (6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity with the tester on
Environmental Specifications
Operating temperature* -18 to 45°C
Non-operating temperature -30 to 60°C
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with AC adapter
Storage altitude 12,000 m
EMC EN 61326-1
* Using battery power. With AC power: 0°C to 45°C. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35°C for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
Click here for complete specifications on the Fluke Networks OFP-SM

What's included with the Fluke Networks OFP-SM

  • Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Gold Product Support

Gold Support for your OptiFiber Pro OTDR allows you to make the most of your purchase while ensuring a higher return on your investment. You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.

What do you get with Gold Support for yourOptiFiber Pro OTDR and fiber module(s)?

Annual Calibration and Factory Refresh - ISO 9001 standards compliance requires annual unit calibration. Keeping your Fiber modules calibrated is critical to ensure accuracy when testing fiber networks. Our calibration processes are ISO-9001 controlled and designed to certify that your OptiFiber Pro OTDR and fiber module(s) meet all published specifications. When you schedule calibration for your OptiFiber Pro OTDR and covered fiber module(s) we will set you up to receive a loaner* unit while your OptiFiber Pro OTDR and covered fiber module(s) are precisely calibrated to factory specifications (calibration certificate provide - calibration traceable with data available for extra charge), repaired as necessary with genuine OEM repair parts, upgraded with all of the latest software and firmware then cleaned and performance verified. In addition, all accessories that came with your OptiFiber Pro OTDR will be tested and replaced if faulty or defective. *Loaner unit for calibration is currently only available in the U.S., and must be scheduled.

Repairs and loaner equipment - If yourOptiFiber Pro OTDR should fail, we'll deliver a loaner unit via next-day delivery to keep you up and running. We'll repair yourOptiFiber Pro OTDR and replace defective or faulty accessories at no charge, with first on bench" priority, and return it to you - all shipping paid by Fluke Networks.

Gold Lifetime BuyBack Guarantee - Buy the tools you need now knowing that Fluke Networks will buy it back when it’s time for a new one. Get 100% cash back within 30 days, 60% within 1 year, and 15% after a year for the life of your tester covered by Gold. (Full terms and conditions can be found at www.flukenetworks.com/GoldBuyBack) (Currently not available within Asia)

Access to live 24 x 7 technical support - Extend the expertise of your staff. Gold Support includes direct, immediate telephone access to our world-class Technical Assistance Center (TAC), direct access only available to Gold Members. Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night when most network changes are implemented, to answer complex troubleshooting questions helping you get the most out of your OptiFiber Pro OTDR and understand the results you are seeing.

Accessory Replacement - Some accessories are essential to your OptiFiber Pro OTDR. The normal warranty on accessories is 90 days, but parts and accessories that shipped with your tester will be replaced free of charge with Gold Support once qualified as defective by our technical assistance center.

Software upgrades - Your OptiFiber Pro OTDR will never be out of date. You'll receive all software upgrades free.

Unlimited access to our Knowledge Base -You'll have an open door to valuable proprietary information we've gathered from helping customers over the years. It also includes helpful technical articles written by our experts.

Member Only promotions -Your membership qualifies you for Members Only promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.

Ensure that you are getting the most out of your OptiFiber Pro OTDRwith Gold Support Services. Buy Gold Support Today.

Ask a question about Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Customer Reviews for the Fluke Networks OFP-SM

Fluke Networks OptiFiber Pro OTDR Offers

OptiFiber® Pro is the industry’s first OTDR built from the ground up to meet the challenges of enterprise fiber infrastructures. This troubleshooting and certification tool combines uncomplicated power, unparalleled efficiency and the exact functions needed for troubleshooting campus, data center and storage fiber networks.

The OptiFiber® Pro OTDR elevates fiber testing with the industry’s only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Features

  • Extremely short event and attenuation dead zone
  • Two second trace per wavelength
  • DataCenter OTDR™ mode
  • Graphical EventMap™ view
  • Dynamic project and user profile management
  • On-screen help with corrective actions
  • FiberInspector™ probe

Features


Smartphone User Interface

Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.

Advantages:

  • Single-touch tap and swipe control for selecting and scrolling menu items
  • Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
  • Task-focused design to reduce back and forth navigation through screens
  • Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
  • Context sensitive on-screen help that gives users additional details or problem resolution suggestions

Optimized for the Datacenter

Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.

With a simple one-touch selection, users enter DataCenter OTDR mode - without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters - end-detection algorithms, pulse widths, etc - without getting confused by the short links or number of connectors.

Advantages:

  • Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
  • DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
  • The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

Unique Certification with Fexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project - defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  • Full OTDR capability that certifies fiber performance based on job assignment for each operator
  • Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  • Easy monitoring of job progress with pass/fail results
  • On-screen report generation and upload to LinkWare™ application

Other Key Features

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software
Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

FiberInspector™ probe
OptiFiber Pro’s video inspection system examines patch cords and patch panel bulkheads to avoid the number one cause of fiber link failure – contamination. Significant time is saved because the probe is inserted directly into the patch panel’s bulkhead to examine installed fiber terminations without disassembling the patch panel. Technicians assign a pass or fail grade to the fiber, append a comment and save it for use in certification reports.

Specifications

OTDR Specifications
Multimode module Singlemode module Quad module
Wavelengths 850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic Range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max Distance Range Setting 40 km 130 km MM: 40 km
SM: 130 km
Distance Measurement Range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample Resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse Widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Rime (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
  2. Measured at ± 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.
FiberInspector Probe Specifications
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source TFS mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 x 1.5 in (1175 x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32 to 122°F (0 to 50 °C)
Storage: -4 to 158°F (-20 to 70°C)
Certifications CE (when used with the mainframe)
VFL Specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2
General Specifications
Weight 3lbs, 5 oz (1.28 kg)
Dimensions 2.625 x 5.25 x 11.0 in (6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity with the tester on
Environmental Specifications
Operating temperature* -18 to 45°C
Non-operating temperature -30 to 60°C
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with AC adapter
Storage altitude 12,000 m
EMC EN 61326-1
* Using battery power. With AC power: 0°C to 45°C. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35°C for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
Click here for complete specifications on the Fluke Networks OFP-SM

What's included with the Fluke Networks OFP-SM

  • Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Gold Product Support

Gold Support for your OptiFiber Pro OTDR allows you to make the most of your purchase while ensuring a higher return on your investment. You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.

What do you get with Gold Support for yourOptiFiber Pro OTDR and fiber module(s)?

Annual Calibration and Factory Refresh - ISO 9001 standards compliance requires annual unit calibration. Keeping your Fiber modules calibrated is critical to ensure accuracy when testing fiber networks. Our calibration processes are ISO-9001 controlled and designed to certify that your OptiFiber Pro OTDR and fiber module(s) meet all published specifications. When you schedule calibration for your OptiFiber Pro OTDR and covered fiber module(s) we will set you up to receive a loaner* unit while your OptiFiber Pro OTDR and covered fiber module(s) are precisely calibrated to factory specifications (calibration certificate provide - calibration traceable with data available for extra charge), repaired as necessary with genuine OEM repair parts, upgraded with all of the latest software and firmware then cleaned and performance verified. In addition, all accessories that came with your OptiFiber Pro OTDR will be tested and replaced if faulty or defective. *Loaner unit for calibration is currently only available in the U.S., and must be scheduled.

Repairs and loaner equipment - If yourOptiFiber Pro OTDR should fail, we'll deliver a loaner unit via next-day delivery to keep you up and running. We'll repair yourOptiFiber Pro OTDR and replace defective or faulty accessories at no charge, with first on bench" priority, and return it to you - all shipping paid by Fluke Networks.

Gold Lifetime BuyBack Guarantee - Buy the tools you need now knowing that Fluke Networks will buy it back when it’s time for a new one. Get 100% cash back within 30 days, 60% within 1 year, and 15% after a year for the life of your tester covered by Gold. (Full terms and conditions can be found at www.flukenetworks.com/GoldBuyBack) (Currently not available within Asia)

Access to live 24 x 7 technical support - Extend the expertise of your staff. Gold Support includes direct, immediate telephone access to our world-class Technical Assistance Center (TAC), direct access only available to Gold Members. Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night when most network changes are implemented, to answer complex troubleshooting questions helping you get the most out of your OptiFiber Pro OTDR and understand the results you are seeing.

Accessory Replacement - Some accessories are essential to your OptiFiber Pro OTDR. The normal warranty on accessories is 90 days, but parts and accessories that shipped with your tester will be replaced free of charge with Gold Support once qualified as defective by our technical assistance center.

Software upgrades - Your OptiFiber Pro OTDR will never be out of date. You'll receive all software upgrades free.

Unlimited access to our Knowledge Base -You'll have an open door to valuable proprietary information we've gathered from helping customers over the years. It also includes helpful technical articles written by our experts.

Member Only promotions -Your membership qualifies you for Members Only promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.

Ensure that you are getting the most out of your OptiFiber Pro OTDRwith Gold Support Services. Buy Gold Support Today.

Ask a question about Fluke Networks OFP-SM OptiFiber Pro Singlemode OTDR

Customer Reviews for the Fluke Networks OFP-SM

More Fluke Networks Products

Calibration Lab