Rugged and reliable, this power kit offers simultaneous True RMS current and voltage measurement (AC, AC+DC, and DC), plus a resolution of 60,000 digits. In addition, precisely acquire crucial power quantities with this kit equipped with a True RMS multimeter and AC/DC current sensor clamp.
Rugged and reliable, this power kit offers simultaneous True RMS current and voltage measurement (AC, AC+DC, and DC), plus a resolution of 60,000 digits. In addition, precisely acquire crucial power quantities with this kit equipped with a True RMS multimeter and AC/DC current sensor clamp.
Measure everything you need with just this kit equipped for current, voltage, temperature, decibel level, and much more. Additionally, the handheld device offers remote control, an illuminated display, and built-in memory storage to help make all your checks flow smoothly.
Features
Power and energy measurement
A compact power meter for direct and alternating current in single-phase systems. The electrical circuit can be connected either directly, or via a current transformer. If a current transformer is connected to the multimeter (mA/A input), all current and power displays are represented with the correct value based upon the selected transformation ratio. Universal power measurement includes the following measuring functions: active, reactive and apparent power, power factor and energy. Beyond this, the mean power value can be generated over a specified time period (e.g. 15 minutes), and the corresponding maximum value can be recorded along with time of occurrence.
Systematic voltage quality analysis
Equipped with a function for acquiring and recording power disturbances which is unique amongst the handheld multimeters. It allows for simultaneous, continuous recording of voltage characteristics and event-triggered recording of the following disturbances:
Harmonic analysis
In the current measurement (A) switch positions, harmonic analysis is performed approximately once per second using 32 sampling values per mains period (adjustable to 16.7, 50, 60 or 400 Hz). FFT (fast Fourier transformation) makes oscillations up to the 15th harmonic available to this end. These are used to calculate the RMS values of the fundamental harmonic (HD 1) and the individual higher harmonics (HD 2 to 15), as well as total harmonic distortion (THD). RMS values and harmonic components are displayed in each case (RMS values relative to the RMS value of the fundamental harmonic).
Convenient triple display
The momentary measured value and up to two additional values are displayed simultaneously, for example:
Or in the case of power measurement:
User safety and overload protection
Dangerous alternating contact voltages of greater then 30 V and direct voltages of greater than 35 V are indicated visually. Overload protection safeguards the instrument in all measuring functions for up to 600 V. Voltages of greater than 600 V and currents of greater than 10 or 16 A are indicated acoustically. Dangerous contact voltages are indicated when the 1 kHz low-pass filter has been activated. FUSE appears at the display if the fuse for the current measuring input blows. Switching between high and low impedance measuring functions is disabled in the vent of dangerous contact voltage.
Three connector jacks with automatic blocking sockets (ABS)
All current ranges are implemented via a single connector jack which prevents any possibility of operator error. Auto-ranging is available in all current measuring ranges. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well as selection of the wrong measured quantity. Danger to the user, the instrument and the device under test resulting from operator error is thus ruled out. Exceptions include switch positions W, Wh and A.
RMS value with distorted waveshape
The utilized measuring method allows for waveshape independent RMS measurement (TRMS AC and AC+DC) for voltage up to 100 kHz and current (up to 10 kHz and up to CF = 10).
Activatable filter for V AC measurement
A 1 kHz low-pass filter can be activated if required, for example when measuring motor voltage at electronic frequency converters. The input signal is checked by a voltage comparator for dangerous voltages as long as the low-pass filter is activated. A high voltage symbol appears at the display if dangerous voltage is present.
Measuring of 5 V square-wave signals
This function makes it possible to test circuits and transmission cables by measuring the frequency and the duty cycle of pulses with amplitudes of 2 to 5 V and frequencies of 1 Hz to 1 MHz.
Fast acoustic continuity test
Testing for short circuiting and interruption is possible with the selector switch in the on position. The threshold value for acoustic signaling can be set to 1, 10, 20 to 500 Ω in 10 Ω steps.
Automatic/manual measuring range selection
Measured quantities are selected by means of a rotary switch and a function key. The measuring range is automatically matched to the measured values. The measuring range can also be selected and locked manually with a key.
Peak value monitoring for automatic and manual measuring range selection
The peak value is measured in addition to RMS measurement in the V/A DC, AC and AC+D functions, as well as for power measurement. If the peak value exceeds the valid range of the corresponding measuring path, this instrument is switched up one range, even if the displayed RMS measured value has not yet reached the threshold value. If the momentary measuring range is manually locked, (-)OL appears to indicate the peak value.
This assures that measurement only takes place in the permissible range for these functions (e.g. during measurement of a signal with a high crest factor or measurement of the DC component of high AC+DC voltages).
Measurement with current transformer clamps and sensors
Current transformer clamps and sensors are used for current measurements without interrupting the circuit under test, and for high amperages (>16 A). Offers convenient measurement with current clamps. The measured current value is automatically calculated for the user with the help of the adjustable clamp factor.
Automatic storage of measured values
The DATA function automatically saves the digitally displayed measured value after settling in. Acoustic signaling is also used to indicate whether the new measured value deviates from the initial reference value less or more than 0.1% of the measuring range.
Storage of minimum-maximum values
Comparable to the slave-pointer function of an analog instrument, the device saves the highest and lowest measured values after the Min-Max function has been activated or reset. These extreme values and their time stamps can be queried at the display.
Memory mode operation
Equipped with a quartz-movement synchronized measurement data memory (2048 kB), which has enough capacity for up to 300,000 measured values depending upon configuration. This allows for use of the instrument as an autonomous real-time data logger. Measurement data recording is executed either:
Battery charging status - power saving circuit
The battery charging status is indicated by means of four symbols. The device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable), and if none of the controls are activated during this time (automatic shutdown is deactivated for power and energy measurement as well as for power quality analysis). Automatic shutdown can be disabled by switching the instrument to continuous operation. The standby mode for the infrared interface can be deactivated.
Protective cover for harsh conditions
Protected against damage in the event of impacts or dropping by means of a soft rubber cover with tilt stand and test probe holder. The rubber material also assures that it does not wander if it is set up on a vibrating surface.
Applications
Measuring Function: V | Range: 60, 600 mV, 6, 60, 600 V Resolution at upper range limit (60,000): 1, 10, 100 μV, 1, 10 mV |
Measuring Function: dB | Range: 0.6 to 600 V Resolution at upper range limit (6000): 0.01 dB |
Measuring Function: A | Range: 600 μA, 6, 60, 600 mA, 6, 10 A Resolution at upper range limit (60,000): 10, 100 nA, 1, 10, 100 μA, 1 mA |
Measuring Function: Ω | Range: 600 Ω, 6, 60, 600 kΩ, 6, 60MΩ Resolution at upper range limit (60,000): 10, 100 mΩ, 1, 10, 100 Ω, 1 kΩ |
Measuring Function: F | Range: 60, 600 nF, 6, 60, 600 μF Resolution at upper range limit (6000): 10, 100 pF, 1, 10, 100 nF |
Measuring Function: MHz | Range: 600 Hz to 1 MHz Resolution at upper range limit (60,000): 0.01 to 100 Hz |
Measuring Function: % | Range: 2 to 98%, 5 to 95%, 10 to 90% Resolution at upper range limit (6000): 0.01% |
Internal Clock | Time format: DD.MM.YYYY hh:mm:ss Resolution: 0.1 s Accuracy: ±1 minute/month Temperature influence: 50 ppm/K |
Data Interface | Type: Optical via infrared light through the housing Data transmission: Serial, bidirectional (not IrDa compatible) Protocol: Device specific Baud rate: 38,400 baud Functions: Select/query measuring functions and parameters, query momentary measurement data, read out stored measurement data |
Internal Measured Value Storage | Memory capacity: 16 MBit for approximately 300,000 measured values with indication of date and time |
Power Supply | Battery: 2 x 1.5 V AA batteries, alkaline manganese per IEC LR6 (2 x 1.2 V NiMH rechargeable batteries also possible) Life: With alkaline manganese: approximately 120 hrs |
Display | Trans-reflective LCD panel (2.56 x 1.42" [65 x 36 mm]) with display of up to 3 measured values, unit of measure, type of current and various special functions |
Acoustic Signals | For voltage: Intermittent signal at above 600 V For current Intermittent signal at above 10 A; continuous signal at above 16 A |
Fuse | Fuse link: FF (UR) 10 A/1000 V AC/DC, 0.4 x 1.5" (10 x 38 mm), breaking capacity of at least 30 kA at 1000 V AC/DC, protects the current measurement input in the 600 μA to 10 A ranges |
Electrical Safety | Per IEC 61010-1:2010/VDE 0411-1:2011 Protection class: II Measuring category: CAT III, CAT IV Operating voltage: 600 V, 300 V Pollution degree: 2 Test voltage: 5.2 kV~ |
Electromagnetic Compatibility (EMC) | Interference emission: EN 61326-1: 2013, class B Interference immunity: EN 61326-1: 2013; EN 61326-2-1: 2013 |
Ambient Conditions | Accuracy range: 32 to 104°F (0 to 40°C) Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -13 to 158°F (-25 to 70°C) without batteries Relative humidity: 40 to 75%, no condensation allowed Elevation: To 6561.68' (2000 m) Deployment: Indoors, except within specified ambient conditions |
Protection | Housing: IP52 |
Housing | Impact resistant plastic (ABS) |
Dimensions | 7.87 x 3.43 x 1.77" (200 x 87 x 45 mm), without rubber holster |
Weight | Approximately 0.88 lbs (0.4 kg) with batteries |
Measuring Function: V | Range: 60, 600 mV, 6, 60, 600 V Resolution at upper range limit (60,000): 1, 10, 100 μV, 1, 10 mV |
Measuring Function: dB | Range: 0.6 to 600 V Resolution at upper range limit (6000): 0.01 dB |
Measuring Function: A | Range: 600 μA, 6, 60, 600 mA, 6, 10 A Resolution at upper range limit (60,000): 10, 100 nA, 1, 10, 100 μA, 1 mA |
Measuring Function: Ω | Range: 600 Ω, 6, 60, 600 kΩ, 6, 60MΩ Resolution at upper range limit (60,000): 10, 100 mΩ, 1, 10, 100 Ω, 1 kΩ |
Measuring Function: F | Range: 60, 600 nF, 6, 60, 600 μF Resolution at upper range limit (6000): 10, 100 pF, 1, 10, 100 nF |
Measuring Function: MHz | Range: 600 Hz to 1 MHz Resolution at upper range limit (60,000): 0.01 to 100 Hz |
Measuring Function: % | Range: 2 to 98%, 5 to 95%, 10 to 90% Resolution at upper range limit (6000): 0.01% |
Internal Clock | Time format: DD.MM.YYYY hh:mm:ss Resolution: 0.1 s Accuracy: ±1 minute/month Temperature influence: 50 ppm/K |
Data Interface | Type: Optical via infrared light through the housing Data transmission: Serial, bidirectional (not IrDa compatible) Protocol: Device specific Baud rate: 38,400 baud Functions: Select/query measuring functions and parameters, query momentary measurement data, read out stored measurement data |
Internal Measured Value Storage | Memory capacity: 16 MBit for approximately 300,000 measured values with indication of date and time |
Power Supply | Battery: 2 x 1.5 V AA batteries, alkaline manganese per IEC LR6 (2 x 1.2 V NiMH rechargeable batteries also possible) Life: With alkaline manganese: approximately 120 hrs |
Display | Trans-reflective LCD panel (2.56 x 1.42" [65 x 36 mm]) with display of up to 3 measured values, unit of measure, type of current and various special functions |
Acoustic Signals | For voltage: Intermittent signal at above 600 V For current Intermittent signal at above 10 A; continuous signal at above 16 A |
Fuse | Fuse link: FF (UR) 10 A/1000 V AC/DC, 0.4 x 1.5" (10 x 38 mm), breaking capacity of at least 30 kA at 1000 V AC/DC, protects the current measurement input in the 600 μA to 10 A ranges |
Electrical Safety | Per IEC 61010-1:2010/VDE 0411-1:2011 Protection class: II Measuring category: CAT III, CAT IV Operating voltage: 600 V, 300 V Pollution degree: 2 Test voltage: 5.2 kV~ |
Electromagnetic Compatibility (EMC) | Interference emission: EN 61326-1: 2013, class B Interference immunity: EN 61326-1: 2013; EN 61326-2-1: 2013 |
Ambient Conditions | Accuracy range: 32 to 104°F (0 to 40°C) Operating temperature range: 14 to 122°F (-10 to 50°C) Storage temperature range: -13 to 158°F (-25 to 70°C) without batteries Relative humidity: 40 to 75%, no condensation allowed Elevation: To 6561.68' (2000 m) Deployment: Indoors, except within specified ambient conditions |
Protection | Housing: IP52 |
Housing | Impact resistant plastic (ABS) |
Dimensions | 7.87 x 3.43 x 1.77" (200 x 87 x 45 mm), without rubber holster |
Weight | Approximately 0.88 lbs (0.4 kg) with batteries |