Leviton 2000 Series Three Phase Meters and Kits

Leviton 2000 Series Three Phase Meters and Kits

Model Selection

Designed for residential applications, these 100A, 200A, and 400A electric submeters are perfect for metering electric consumption or production for nearly any 120V 2-wire or 120/240V 3-wire application. These revenue-grade single phase (120V 2-wire or 120/240V 3-wire) kWh electric meters make tenant submetering a snap! Available in indoor flush-mount, outdoor surface-mount, or NEMA 4X Multiple Meter Units (MMUs).

Designed for residential applications, these 100A, 200A, and 400A electric submeters are perfect for metering electric consumption or production for nearly any 120V 2-wire or 120/240V 3-wire application. These revenue-grade single phase (120V 2-wire or 120/240V 3-wire) kWh electric meters make tenant submetering a snap! Available in indoor flush-mount, outdoor surface-mount, or NEMA 4X Multiple Meter Units (MMUs).


Leviton 2000 Series Offers

The Leviton VerifEye Series 2000 line of revenue-grade meters meets all measurement and verification-based opportunities — including load management and LEED rating achievement. Designed to provide a simple and effective process for accurately capturing measurements of power consumption, Series 2000 Meters are easy to specify and install for new construction and retrofits.

Leviton meters utilize highly accurate current transformers (CTs) for revenue-grade performance certified to ANSI standards. Competing products use current sensors that do not provide the same level of performance. Leviton offers CTs in solid and split core styles to accommodate all phases of installation and construction.

Solid core CTs are ideal for new construction, when power is not live and wires can easily be threaded through the core. Split core CTs can be installed at any time without having to disconnect wire terminations, making them the optimal choice for retrofitting an existing structure. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Leviton solid core CTs are cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line. The CT "secondary" wires connect to the meter facilitating power and energy calculations. They are compact and cost effective. Solid core CTs are accurate (0.3% maximum error). For installation, power must be de-energized and the circuit opened in order to slip the CT over the power line.

Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Split core CTs can be disassembled or 'split' into halves eliminating the need to turn power off and open the circuit during installation. This time-saving installation is ideal for critical loads that cannot be disconnected. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation.

Every Series 2000 Meter has an installer friendly feedback feature. The red reverse phase indicator acts as an installation diagnostics tool and illuminates if a meter is improperly installed. After installation, the green duty cycle light shows that the meter is collecting the electrical consumption data at the appropriate rate. All 100 and 200 Amp solid core CTs have color-coded labels to easily identify and correctly land the wires at the meter.

Features

  • Measures kWh and demand (optional)
  • Conforms to all applicable standards of ANSI C12.1
  • Reverse energy LED indicator helps ensure proper installation
  • Equipped with an Isolated Pulse Output channel
  • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core CTs that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs (CT's sold separatley)
  • Up to three sets of CTs per phase can be paralleled per meter without the need for a meter multiplier
  • Enclosures include surface mount industrial grade JIC steel indoor and NEMA 4X outdoor
  • Interfaces with numerous communication systems – Hardwired Automatic Meter Reading (AMR) or wireless AMR
  • Large LCD display shows kWh and instantaneous and peak demand (optionally) with manual keyed reset
  • Load Indicator LED verifies meter functionality
  • Reverse Phase Indicator LED illuminates if the meter is improperly installed
  • UL/cUL Listed for UL 916 Energy Monitoring Equipment
  • Ten year warranty

Applications

Ideal for the following applications: Load Profiling and Benchmarking, Usage Aggregation, Tenant Cost Allocation, Measurement and Verification, Energy Conservation and Cost Reduction, Green Building Initiatives and Government Mandates

What's included with the Leviton Leviton 2000 Series

  • Leviton 2000 Series Three Phase Meters and Kits

Ask a question about Leviton 2000 Series Three Phase Meters and Kits

Customer Reviews for the Leviton Leviton 2000 Series

Leviton 2000 Series Offers

The Leviton VerifEye Series 2000 line of revenue-grade meters meets all measurement and verification-based opportunities — including load management and LEED rating achievement. Designed to provide a simple and effective process for accurately capturing measurements of power consumption, Series 2000 Meters are easy to specify and install for new construction and retrofits.

Leviton meters utilize highly accurate current transformers (CTs) for revenue-grade performance certified to ANSI standards. Competing products use current sensors that do not provide the same level of performance. Leviton offers CTs in solid and split core styles to accommodate all phases of installation and construction.

Solid core CTs are ideal for new construction, when power is not live and wires can easily be threaded through the core. Split core CTs can be installed at any time without having to disconnect wire terminations, making them the optimal choice for retrofitting an existing structure. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Leviton solid core CTs are cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line. The CT "secondary" wires connect to the meter facilitating power and energy calculations. They are compact and cost effective. Solid core CTs are accurate (0.3% maximum error). For installation, power must be de-energized and the circuit opened in order to slip the CT over the power line.

Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Split core CTs can be disassembled or 'split' into halves eliminating the need to turn power off and open the circuit during installation. This time-saving installation is ideal for critical loads that cannot be disconnected. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation.

Every Series 2000 Meter has an installer friendly feedback feature. The red reverse phase indicator acts as an installation diagnostics tool and illuminates if a meter is improperly installed. After installation, the green duty cycle light shows that the meter is collecting the electrical consumption data at the appropriate rate. All 100 and 200 Amp solid core CTs have color-coded labels to easily identify and correctly land the wires at the meter.

Features

  • Measures kWh and demand (optional)
  • Conforms to all applicable standards of ANSI C12.1
  • Reverse energy LED indicator helps ensure proper installation
  • Equipped with an Isolated Pulse Output channel
  • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core CTs that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs (CT's sold separatley)
  • Up to three sets of CTs per phase can be paralleled per meter without the need for a meter multiplier
  • Enclosures include surface mount industrial grade JIC steel indoor and NEMA 4X outdoor
  • Interfaces with numerous communication systems – Hardwired Automatic Meter Reading (AMR) or wireless AMR
  • Large LCD display shows kWh and instantaneous and peak demand (optionally) with manual keyed reset
  • Load Indicator LED verifies meter functionality
  • Reverse Phase Indicator LED illuminates if the meter is improperly installed
  • UL/cUL Listed for UL 916 Energy Monitoring Equipment
  • Ten year warranty

Applications

Ideal for the following applications: Load Profiling and Benchmarking, Usage Aggregation, Tenant Cost Allocation, Measurement and Verification, Energy Conservation and Cost Reduction, Green Building Initiatives and Government Mandates

What's included with the Leviton Leviton 2000 Series

  • Leviton 2000 Series Three Phase Meters and Kits

Ask a question about Leviton 2000 Series Three Phase Meters and Kits

Customer Reviews for the Leviton Leviton 2000 Series

More Leviton Products

Calibration Lab